From bench to bedside: 64Cu/177Lu 1C1m-Fc anti TEM-1: mice-to-human dosimetry extrapolations for future theranostic applications.

Détails

Ressource 1Télécharger: 37314509_BIB_91574209E2BB.pdf (1368.82 [Ko])
Etat: Public
Version: Final published version
Licence: CC BY 4.0
ID Serval
serval:BIB_91574209E2BB
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
From bench to bedside: 64Cu/177Lu 1C1m-Fc anti TEM-1: mice-to-human dosimetry extrapolations for future theranostic applications.
Périodique
EJNMMI research
Auteur⸱e⸱s
Gnesin S., Chouin N., Cherel M., Dunn S.M., Schaefer N., Faivre-Chauvet A., Prior J.O., Delage J.A.
ISSN
2191-219X (Print)
ISSN-L
2191-219X
Statut éditorial
Publié
Date de publication
14/06/2023
Peer-reviewed
Oui
Volume
13
Numéro
1
Pages
59
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: epublish
Résumé
The development of diagnostic and therapeutic radiopharmaceuticals is an hot topic in nuclear medicine. Several radiolabeled antibodies are under development necessitating both biokinetic and dosimetry extrapolations for effective human translation. The validation of different animal-to-human dosimetry extrapolation methods still is an open issue. This study reports the mice-to-human dosimetry extrapolation of <sup>64</sup> Cu/ <sup>177</sup> Lu 1C1m-Fc anti-TEM-1 for theranostic application in soft-tissue sarcomas. We adopt four methods; direct mice-to-human extrapolation (M1); dosimetry extrapolation considering a relative mass scaling factor (M2), application of a metabolic scaling factor (M3) and combination of M2 and M3 (M4). Predicted in-human dosimetry for the [ <sup>64</sup> Cu]Cu-1C1m-Fc resulted in an effective dose of 0.05 mSv/MBq. Absorbed dose (AD) extrapolation for the [ <sup>177</sup> Lu]Lu-1C1m-Fc indicated that the AD of 2 Gy and 4 Gy to the red-marrow and total-body can be reached with 5-10 GBq and 25-30 GBq of therapeutic activity administration respectively depending on applied dosimetry method. Dosimetry extrapolation methods provided significantly different absorbed doses in organs. Dosimetry properties for the [ <sup>64</sup> Cu]Cu-1C1m-Fc are suitable for a diagnostic in-human use. The therapeutic application of [ <sup>177</sup> Lu]Lu-1C1m-Fc presents challenges and would benefit from further assessments in animals' models such as dogs before moving into the clinic.
Mots-clé
Clinical translation, Copper-64, Dose extrapolation, Dosimetry, Fusion protein antibody, Lutetium-177, PET imaging, Radioimmunotherapy, Theranostic, Tumor endothelial marker 1
Pubmed
Web of science
Open Access
Oui
Création de la notice
15/06/2023 17:40
Dernière modification de la notice
23/01/2024 8:30
Données d'usage