Time constant histograms from the forced expired volume signal: a clinical evaluation.

Détails

ID Serval
serval:BIB_90601157D7FC
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Time constant histograms from the forced expired volume signal: a clinical evaluation.
Périodique
European Respiratory Journal
Auteur⸱e⸱s
Revelly J.P., Feihl F., Liebling T., Perret C.
ISSN
0903-1936[print], 0903-1936[linking]
Statut éditorial
Publié
Date de publication
1989
Volume
2
Numéro
6
Pages
536-542
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
We evaluated a multicompartment analysis of forced expiration, based on modelling the lung as a set of twenty parallel compartments emptying exponentially with time constants ranging from 0.1-10 s; the forced expired volume signal was represented by a histogram showing the fraction of forced vital capacity as a function of compartmental time constants. We applied this technique to 80 healthy and 12 asthmatic subjects. The histograms computed from three consecutive forced expirations were poorly reproducible in 18 of the 80 healthy and 2 of the 12 asthmatic subjects. In the asthmatics, the time constant histograms conveyed no additional information on bronchial obstruction, beyond that already present in standard spirometric indices. A simulation study showed a high sensitivity of the histograms to the truncation of the terminal part of forced expiration. We conclude that the usefulness of the time constant histogram technique appears doubtful.
Mots-clé
Adult, Asthma/physiopathology, Female, Forced Expiratory Volume, Humans, Male, Reproducibility of Results, Spirometry
Pubmed
Web of science
Création de la notice
25/01/2008 9:37
Dernière modification de la notice
20/08/2019 14:53
Données d'usage