New combined serum creatinine and cystatin C quadratic formula for GFR assessment in children.
Détails
ID Serval
serval:BIB_8F8ECFAFC64E
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
New combined serum creatinine and cystatin C quadratic formula for GFR assessment in children.
Périodique
Clinical Journal of the American Society of Nephrology
ISSN
1555-905X (Electronic)
ISSN-L
1555-9041
Statut éditorial
Publié
Date de publication
2014
Peer-reviewed
Oui
Volume
9
Numéro
1
Pages
54-63
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Publication Status: ppublish
Résumé
BACKGROUND AND OBJECTIVES: The estimated GFR (eGFR) is important in clinical practice. To find the best formula for eGFR, this study assessed the best model of correlation between sinistrin clearance (iGFR) and the solely or combined cystatin C (CysC)- and serum creatinine (SCreat)-derived models. It also evaluated the accuracy of the combined Schwartz formula across all GFR levels.
DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Two hundred thirty-eight iGFRs performed between January 2012 and April 2013 for 238 children were analyzed. Regression techniques were used to fit the different equations used for eGFR (i.e., logarithmic, inverse, linear, and quadratic). The performance of each model was evaluated using the Cohen κ correlation coefficient and the percentage reaching 30% accuracy was calculated.
RESULTS: The best model of correlation between iGFRs and CysC is linear; however, it presents a low κ coefficient (0.24) and is far below the Kidney Disease Outcomes Quality Initiative targets to be validated, with only 84% of eGFRs reaching accuracy of 30%. SCreat and iGFRs showed the best correlation in a fitted quadratic model with a κ coefficient of 0.53 and 93% accuracy. Adding CysC significantly (P<0.001) increased the κ coefficient to 0.56 and the quadratic model accuracy to 97%. Therefore, a combined SCreat and CysC quadratic formula was derived and internally validated using the cross-validation technique. This quadratic formula significantly outperformed the combined Schwartz formula, which was biased for an iGFR≥91 ml/min per 1.73 m(2).
CONCLUSIONS: This study allowed deriving a new combined SCreat and CysC quadratic formula that could replace the combined Schwartz formula, which is accurate only for children with moderate chronic kidney disease.
DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Two hundred thirty-eight iGFRs performed between January 2012 and April 2013 for 238 children were analyzed. Regression techniques were used to fit the different equations used for eGFR (i.e., logarithmic, inverse, linear, and quadratic). The performance of each model was evaluated using the Cohen κ correlation coefficient and the percentage reaching 30% accuracy was calculated.
RESULTS: The best model of correlation between iGFRs and CysC is linear; however, it presents a low κ coefficient (0.24) and is far below the Kidney Disease Outcomes Quality Initiative targets to be validated, with only 84% of eGFRs reaching accuracy of 30%. SCreat and iGFRs showed the best correlation in a fitted quadratic model with a κ coefficient of 0.53 and 93% accuracy. Adding CysC significantly (P<0.001) increased the κ coefficient to 0.56 and the quadratic model accuracy to 97%. Therefore, a combined SCreat and CysC quadratic formula was derived and internally validated using the cross-validation technique. This quadratic formula significantly outperformed the combined Schwartz formula, which was biased for an iGFR≥91 ml/min per 1.73 m(2).
CONCLUSIONS: This study allowed deriving a new combined SCreat and CysC quadratic formula that could replace the combined Schwartz formula, which is accurate only for children with moderate chronic kidney disease.
Pubmed
Web of science
Open Access
Oui
Création de la notice
14/01/2014 14:59
Dernière modification de la notice
20/08/2019 14:53