Imagerie pour le traitement stéréotaxique des schwannomes vestibulaires. Facteurs d'erreur et corrections [Imaging for stereotaxic treatment of vestibular schwannomas. Error factors and corrections].

Détails

ID Serval
serval:BIB_888C15C87B3E
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Imagerie pour le traitement stéréotaxique des schwannomes vestibulaires. Facteurs d'erreur et corrections [Imaging for stereotaxic treatment of vestibular schwannomas. Error factors and corrections].
Périodique
Neuro-Chirurgie
Auteur⸱e⸱s
Wikler D., Metens T., David P., Levivier M.
ISSN
0028-3770 (Print)
ISSN-L
0028-3770
Statut éditorial
Publié
Date de publication
2004
Peer-reviewed
Oui
Volume
50
Numéro
2-3 Pt 2
Pages
282-288
Langue
français
Notes
Publication types: English Abstract ; Journal Article
Publication Status: ppublish
Résumé
BACKGROUND AND PURPOSE: Gamma Knife radiosurgery treatment of vestibular schwannomas requires high accuracy for the prescribed dose definition and delivery. The main factors contributing to the error are the anatomical distortions of imaging modalities used for treatment planning. Imaging limitations and error factors are reviewed and detailed. Multimodality rationale for the delineation of vestibular schwannomas and surrounding structures are assessed. Quality control strategies are discussed and a distortion correction technique using a radiological phantom is presented.
METHODS: Computed tomography is considered as the reference for spatial accuracy after appropriate scanner quality control using the stereotaxic fiducials system. Magnetic resonance imaging pulse sequence distortions are measured with a phantom designed for 3D non-linear local distortion evidence. A distortion correction transformation is computed from the phantom images and applied to the patient images. Results are verified using the stereotaxic fiducials system.
RESULTS: Fiducials registration errors show spatial accuracy improvement, approaching computed tomography quality, after distortion correction of magnetic resonance images.
CONCLUSIONS: The multimodal imaging approach for the dose planning of vestibular schwannomas radiosurgery treatment is relevant. Quality control of spatial accuracy for imaging modalities is mandatory and realistic in clinical routine.
Mots-clé
Ear Neoplasms/pathology, Ear Neoplasms/radiography, Humans, Magnetic Resonance Imaging, Neuroma, Acoustic/pathology, Neuroma, Acoustic/radiography, Postoperative Complications/prevention & control, Radiosurgery/instrumentation, Tomography, X-Ray Computed