Stent by stent crush: procedural outcome and angiographic follow-up

Détails

ID Serval
serval:BIB_884E68E6851B
Type
Article: article d'un périodique ou d'un magazine.
Sous-type
Etude de cas (case report): rapporte une observation et la commente brièvement.
Collection
Publications
Institution
Titre
Stent by stent crush: procedural outcome and angiographic follow-up
Périodique
Catheterization and Cardiovascular Diagnosis
Auteur⸱e⸱s
Eeckhout  E., Vogt  P.
ISSN
0098-6569 (Print)
Statut éditorial
Publié
Date de publication
09/1998
Volume
45
Numéro
1
Pages
54-6
Notes
Case Reports
Journal Article --- Old month value: Sep
Résumé
Rewiring of an occluded and incompletely deployed coronary stent with a sharp and/or tortuous entrance angle may be difficult in the emergency setting. We report the case of a patient who experienced subacute stent thrombosis in the proximal right coronary artery. Incorrect rewiring resulted in stent crush after conventional balloon angioplasty at lesion site. In order to improve the angiographic result parallel stent placement was performed. Repeat angiography at 6 months demonstrated vessel patency without restenosis.
Mots-clé
Angioplasty, Transluminal, Percutaneous Coronary/*instrumentation *Coronary Angiography Equipment Design Equipment Failure Analysis Follow-Up Studies Graft Occlusion, Vascular/radiography/*therapy Humans Image Processing, Computer-Assisted Male Middle Aged Retreatment *Stents
Pubmed
Web of science
Création de la notice
28/01/2008 9:51
Dernière modification de la notice
20/08/2019 14:47
Données d'usage