Fifteen-year follow-up after anterior chamber phakic intraocular lens implantation in one and LASIK in the fellow eye.
Détails
ID Serval
serval:BIB_872CBA67A892
Type
Article: article d'un périodique ou d'un magazine.
Sous-type
Etude de cas (case report): rapporte une observation et la commente brièvement.
Collection
Publications
Institution
Titre
Fifteen-year follow-up after anterior chamber phakic intraocular lens implantation in one and LASIK in the fellow eye.
Périodique
Seminars in ophthalmology
ISSN
1744-5205 (Electronic)
ISSN-L
0882-0538
Statut éditorial
Publié
Date de publication
2009
Peer-reviewed
Oui
Volume
24
Numéro
6
Pages
231-233
Langue
anglais
Notes
Publication types: Case Reports ; Journal Article
Publication Status: ppublish
Publication Status: ppublish
Résumé
To report a patient fifteen years after anterior chamber phakic intraocular lens (AC-PIOL) implantation in one and laser in situ keratomileusis (LASIK) in the fellow eye.
Case report.
A 56-year-old male underwent AC-PIOL implantation in one eye and LASIK in the fellow eye fifteen years ago. Preoperative uncorrected visual acuity (UCVA) was finger count in both eyes. Preoperative best spectacle-corrected visual acuity (BSCVA) was 20/25 (-16.75 -0.50 x 40) in the LASIK eye and 20/32 (-24.50 -0.50 x 90) in the AC-PIOL eye. Fifteen years postoperatively, UCVA was finger count in the LASIK eye and 20/200 in the AC-PIOL eye, while BSCVA was 20/32 and 20/25, respectively. Endothelial cell density (ECD) was 2020+/-47 in the LASIK eye and 945+/-22 in the AC-PIOL eye.
Both procedures had similar visual outcomes. Furthermore, lower ECD was found in the AC-PIOL eye in comparison to the LASIK eye.
Case report.
A 56-year-old male underwent AC-PIOL implantation in one eye and LASIK in the fellow eye fifteen years ago. Preoperative uncorrected visual acuity (UCVA) was finger count in both eyes. Preoperative best spectacle-corrected visual acuity (BSCVA) was 20/25 (-16.75 -0.50 x 40) in the LASIK eye and 20/32 (-24.50 -0.50 x 90) in the AC-PIOL eye. Fifteen years postoperatively, UCVA was finger count in the LASIK eye and 20/200 in the AC-PIOL eye, while BSCVA was 20/32 and 20/25, respectively. Endothelial cell density (ECD) was 2020+/-47 in the LASIK eye and 945+/-22 in the AC-PIOL eye.
Both procedures had similar visual outcomes. Furthermore, lower ECD was found in the AC-PIOL eye in comparison to the LASIK eye.
Mots-clé
Anterior Chamber/surgery, Cell Count, Endothelial Cells/cytology, Endothelium, Corneal/cytology, Follow-Up Studies, Humans, Keratomileusis, Laser In Situ, Lens Implantation, Intraocular, Male, Middle Aged, Myopia/surgery, Patient Satisfaction, Phakic Intraocular Lenses, Visual Acuity
Pubmed
Web of science
Création de la notice
01/10/2019 16:40
Dernière modification de la notice
06/10/2019 6:26