To evaluate the outcomes after Wichterle Intraocular Lens-Continuous Focus (Medicem, Kamenné Zehrovice, Czech Republic) accommodative bioanalogic intraocular lens implantation.
In this prospective case series, 50 eyes of 25 patients (mean age: 65.3 ± 8.4 years; range: 53 to 83 years) were included. All patients underwent routine cataract surgery and Wichterle Intraocular Lens-Continuous Focus implantation.
Mean follow-up was 11.44 ± 2.46 months (range: 9 to 17 months). Both monocular uncorrected and corrected distance visual acuity statistically and significantly (P < .05) improved from 0.31 ± 0.17 (20/63 Snellen) (range: counting fingers to 0.7) to 0.74 ± 0.19 (20/25 Snellen) (range: 0.2 to 1) and from 0.61 ± 0.19 (20/32 Snellen) (range: 0.2 to 1) to 0.82 ± 0.13 (20/25 Snellen) (range: 0.4 to 1), respectively. Target postoperative refraction was -0.5 diopters (D) and preoperative and 1-year postoperative spherical equivalent refraction were 0.72 ± 2.71 D (range: -7.25 to 2.37 D) and -0.24 ± 0.65 D (range: -1.0 to 1.0 D), respectively. No eyes lost lines of corrected distance visual acuity during the follow-up period, whereas 88% of patients gained one or more lines of corrected distance visual acuity. Uncorrected intermediate and near visual acuity were J2 (Snellen 20/25) or better in 72% of patients. No complications occurred intraoperatively or postoperatively. The evaluation of the mean values of root mean square of third and fourth order higher-order aberrations at 1 year postoperatively revealed a mean negative spherical aberration of -0.18 ± 0.13 μm.
Wichterle Intraocular Lens-Continuous Focus accommodative bioanalogic IOL implantation provides satisfactory visual acuity for far, intermediate, and near distances and the promising results remain stable throughout the follow-up period.
Mots-clé
Accommodation, Ocular/physiology, Aged, Aged, 80 and over, Biocompatible Materials, Capsulorhexis, Female, Humans, Lens Implantation, Intraocular, Lenses, Intraocular, Male, Middle Aged, Phacoemulsification, Prospective Studies, Prosthesis Design, Refraction, Ocular/physiology, Tomography, Optical Coherence, Treatment Outcome, Visual Acuity/physiology