Use of 2D Sensitivity Encoding for Slow-Infusion Contrast-Enhanced Isotropic 3-T Whole-Heart Coronary MR Angiography.

Détails

ID Serval
serval:BIB_7EBFAE70A451
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Use of 2D Sensitivity Encoding for Slow-Infusion Contrast-Enhanced Isotropic 3-T Whole-Heart Coronary MR Angiography.
Périodique
AJR. American Journal of Roentgenology
Auteur⸱e⸱s
Yu J., Paetsch I., Schnackenburg B., Fleck E., Weiss R.G., Stuber M., Jahnke C.
ISSN
1546-3141 (Electronic)
ISSN-L
0361-803X
Statut éditorial
Publié
Date de publication
2011
Volume
197
Numéro
2
Pages
374-382
Langue
anglais
Résumé
OBJECTIVE. The purpose of this study was to improve the blood-pool signal-to-noise ratio (SNR) and blood-myocardium contrast-to-noise ratio (CNR) of slow-infusion 3-T whole-heart coronary MR angiography (MRA).SUBJECTS AND METHODS. In 2D sensitivity encoding (SENSE), the number of acquired k-space lines is reduced, allowing less radiofrequency excitation per cardiac cycle and a longer TR. The former can be exploited for signal enhancement with a higher radiofrequency excitation angle, and the latter leads to noise reduction due to lower data-sampling bandwidth. Both effects contribute to SNR gain in coronary MRA when spatial and temporal resolution and acquisition time remain identical. Numeric simulation was performed to select the optimal 2D SENSE pulse sequence parameters and predict the SNR gain. Eleven patients underwent conventional unenhanced and the proposed 2D SENSE contrast-enhanced coronary MRA acquisition. Blood-pool SNR, blood-myocardium CNR, visible vessel length, vessel sharpness, and number of side branches were evaluated.RESULTS. Consistent with the numeric simulation, using 2D SENSE in contrast-enhanced coronary MRA resulted in significant improvement in aortic blood-pool SNR (unenhanced vs contrast-enhanced, 37.5 +/- 14.7 vs 121.3 +/- 44.0; p < 0.05) and CNR (14.4 +/- 6.9 vs 101.5 +/- 40.8; p < 0.05) in the patient sample. A longer length of left anterior descending coronary artery was visualized, but vessel sharpness, coronary artery coverage, and image quality score were not improved with the proposed approach.CONCLUSION. In combination with contrast administration, 2D SENSE was found effective in improving SNR and CNR in 3-T whole-heart coronary MRA. Further investigation of cardiac motion compensation is necessary to exploit the SNR and CNR advantages and to achieve submillimeter spatial resolution.
Pubmed
Web of science
Création de la notice
22/08/2011 16:18
Dernière modification de la notice
20/08/2019 15:39
Données d'usage