Diagnostic value of the flow profile in the distal descending aorta by phase-contrast magnetic resonance for predicting severe coarctation of the aorta.

Détails

ID Serval
serval:BIB_78A1E50BCA1D
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Diagnostic value of the flow profile in the distal descending aorta by phase-contrast magnetic resonance for predicting severe coarctation of the aorta.
Périodique
Journal of magnetic resonance imaging
Auteur⸱e⸱s
Muzzarelli S., Ordovas K.G., Hope M.D., Meadows J.J., Higgins C.B., Meadows A.K.
ISSN
1522-2586 (Electronic)
ISSN-L
1053-1807
Statut éditorial
Publié
Date de publication
06/2011
Peer-reviewed
Oui
Volume
33
Numéro
6
Pages
1440-1446
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
To compare aortic flow profiles at the level of the proximal descending (PDAo) and distal descending aorta (DDAo) in patients investigated for coarctation of the aorta (CoA), and compare their respective diagnostic value for predicting severe CoA. Diastolic flow decay in the PDAo predicts severe CoA, but flow measurements at this level are limited by flow turbulence, aliasing, and stent-related artifacts.
We studied 49 patients evaluated for CoA with phase contrast magnetic resonance imaging (PC-MRI). Parameters of diastolic flow decay in the PDAo and DDAo were compared. Their respective diagnostic value was compared with the standard reference of transcatheter peak gradient ≥20 mmHg.
Flow measurement in the PDAo required repeated acquisition with adjustment of encoding velocity or location of the imaging plane in 69% of patients; measurement in the DDAo was achieved in single acquisition in all cases. Parameters of diastolic flow decay in the PDAo and DDAo, including rate-corrected (RC) deceleration time and RC flow deceleration yielded a good correlation (r = 0.78; P < 0.01, and r = 0.92; P < 0.01), and a similar diagnostic value for predicting severe CoA. The highest diagnostic accuracy was achieved by RC deceleration time at DDAo (sensitivity 85%, specificity 85%).
Characterization of aortic flow profiles at the DDAo offers a quick and reliable noninvasive means of assessing hemodynamically significant CoA.
Mots-clé
Adolescent, Adult, Aorta, Thoracic/pathology, Aortic Coarctation/diagnosis, Aortic Coarctation/pathology, Blood Flow Velocity, Catheterization, Contrast Media/pharmacology, Diastole, Female, Gadolinium/pharmacology, Hemodynamics, Humans, Magnetic Resonance Imaging/methods, Male, Stents
Pubmed
Web of science
Open Access
Oui
Création de la notice
15/11/2017 16:12
Dernière modification de la notice
23/02/2024 14:07
Données d'usage