The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes.

Détails

ID Serval
serval:BIB_7636DF484127
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes.
Périodique
Medical Engineering & Physics
Auteur⸱e⸱s
Mitton D., Rumelhart C., Hans D., Meunier P.J.
ISSN
1350-4533
Statut éditorial
Publié
Date de publication
1997
Peer-reviewed
Oui
Volume
19
Numéro
5
Pages
464-474
Langue
anglais
Résumé
An animal model (the ewe) was used to study mechanical parameters of cancellous bone specimens. Compression and shear tests were conducted on ewe vertebral trabecular bone (L1-L5) from old ewes (mean age: 9 years) under two different conditions: first, at room temperature in air ("standard" test conditions); and secondly, in a physiological saline bath regulated at 37 degrees C. The parameters obtained under "standard" test conditions with a uniaxial compression test were the mean value of the maximum strength (sigma max = 22.3 (7.06) MPa), Young's modulus (E = 1510 (784) MPa), the strain at maximum strength (epsilon sigma max = 3.21 (0.8) percent) and the energy absorbed during the test (W = 0.3 (0.12) MJ.m-3). No significant change was found when the test was carried out in a saline bath at 37 degrees C (p < 0.0005). An original shear test was performed to evaluate the shear strength which was found to vary from 7.5 (4.7) to 14.6 (8.53) MPa under "standard" test conditions depending on the method of calculation. Testing of the specimens in a 37 degrees C physiological saline bath induced a decrease in the shear strength from 32.5 percent (p < 0.0005) to 37.3 percent (p < 0.0001) of those measured under "standard" test conditions. The non-destructive measurement of the Bone Mineral Density (BMD) accounted for up to 73.3 percent of the maximum compressive strength sigma max and 61.5 percent of the maximum shear strength tau max determined in saline solution at 37 degrees C. These results showed that other parameters influencing the mechanical properties of trabecular bone and its structure appeared to be essential.
Mots-clé
Absorptiometry, Photon, Animals, Bone Density, Compressive Strength, Female, Lumbar Vertebrae, Sheep, Stress, Mechanical, Temperature
Pubmed
Web of science
Création de la notice
02/03/2009 13:33
Dernière modification de la notice
20/08/2019 15:33
Données d'usage