Off-resonance angiography: a new method to depict vessels--phantom and rabbit studies.

Détails

ID Serval
serval:BIB_74E4389DFA9F
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Off-resonance angiography: a new method to depict vessels--phantom and rabbit studies.
Périodique
Radiology
Auteur⸱e⸱s
Korosoglou G., Shah S., Vonken E.J., Gilson W.D., Schär M., Tang L., Kraitchman D.L., Boston R.C., Sosnovik D.E., Weiss R.G., Weissleder R., Stuber M.
ISSN
1527-1315[electronic], 0033-8419[linking]
Statut éditorial
Publié
Date de publication
2008
Volume
249
Numéro
2
Pages
501-509
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, N.I.H., Extramural ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.
Mots-clé
Animals, Contrast Media/administration & dosage, Ferrosoferric Oxide/administration & dosage, Magnetic Resonance Angiography/methods, Nanoparticles/administration & dosage, Phantoms, Imaging, Rabbits, Regression Analysis
Pubmed
Web of science
Création de la notice
02/03/2010 16:04
Dernière modification de la notice
20/08/2019 14:32
Données d'usage