Cardiopulmonary haemodynamics in Tibetans and Han Chinese during rest and exercise.

Détails

ID Serval
serval:BIB_73D653B25190
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Cardiopulmonary haemodynamics in Tibetans and Han Chinese during rest and exercise.
Périodique
The Journal of physiology
Auteur⸱e⸱s
Möller F.N., Fan J.L., Futral J.E., Hodgman C.F., Kayser B., Lovering A.T.
ISSN
1469-7793 (Electronic)
ISSN-L
0022-3751
Statut éditorial
Publié
Date de publication
08/2024
Peer-reviewed
Oui
Volume
602
Numéro
16
Pages
3893-3907
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
During sea-level exercise, blood flow through intrapulmonary arteriovenous anastomoses (IPAVA) in humans without a patent foramen ovale (PFO) is negatively correlated with pulmonary pressure. Yet, it is unknown whether the superior exercise capacity of Tibetans well adapted to living at high altitude is the result of lower pulmonary pressure during exercise in hypoxia, and whether their cardiopulmonary characteristics are significantly different from lowland natives of comparable ancestry (e.g. Han Chinese). We found a 47% PFO prevalence in male Tibetans (n = 19) and Han Chinese (n = 19) participants. In participants without a PFO (n = 10 each group), we measured heart structure and function at rest and peak oxygen uptake ( ), peak power output ( ), pulmonary artery systolic pressure (PASP), blood flow through IPAVA and cardiac output ( ) at rest and during recumbent cycle ergometer exercise at 760 Torr (SL) and at 410 Torr (ALT) barometric pressure in a pressure chamber. Tibetans achieved a higher than Han, and a higher at ALT without differences in heart rate, stroke volume or . Blood flow through IPAVA was generally similar between groups. Increases in PASP and total pulmonary resistance at ALT were comparable between the groups. There were no differences in the slopes of PASP plotted as a function of during exercise. In those without PFO, our data indicate that the superior aerobic exercise capacity of Tibetans over Han Chinese is independent of cardiopulmonary features and more probably linked to differences in local muscular oxygen extraction. KEY POINTS: Patent foramen ovale (PFO) prevalence was 47% in Tibetans and Han Chinese living at 2 275 m. Subjects with PFO were excluded from exercise studies. Compared to Han Chinese, Tibetans had a higher peak workload with acute compression to sea level barometric pressure (SL) and acute decompression to 5000 m altitude (ALT). Comprehensive cardiac structure and function at rest were not significantly different between Han Chinese and Tibetans. Tibetans and Han had similar blood flow through intrapulmonary arteriovenous anastomoses (IPAVA) during exercise at SL. Peak pulmonary artery systolic pressure (PASP) and total pulmonary resistance were different between SL and ALT, with significantly increased PASP for Han compared to Tibetans at ALT. No differences were observed between groups at acute SL and ALT.
Mots-clé
Humans, Male, Exercise/physiology, Tibet, Adult, Hemodynamics/physiology, Rest/physiology, Asian People, Young Adult, Oxygen Consumption/physiology, Cardiac Output/physiology, Altitude, Pulmonary Artery/physiology, East Asian People, altitude, cardiac structure, intrapulmonary arteriovenous anastomoses, pulmonary artery pressure, shunt
Pubmed
Web of science
Création de la notice
28/06/2024 10:49
Dernière modification de la notice
27/08/2024 6:19
Données d'usage