CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy--comparison of image-guidance techniques.

Détails

ID Serval
serval:BIB_697125F521A5
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy--comparison of image-guidance techniques.
Périodique
Radiology
Auteur⸱e⸱s
Binkert C.A., Verdun F.R., Zanetti M., Pfirrmann C.W., Hodler J.
ISSN
0033-8419
Statut éditorial
Publié
Date de publication
2003
Peer-reviewed
Oui
Volume
229
Numéro
1
Pages
153-8
Langue
anglais
Notes
Publication types: Comparative Study ; Journal Article - Publication Status: ppublish
Résumé
PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.
Mots-clé
Adolescent, Adult, Aged, Contrast Media, Female, Fluoroscopy, Humans, Injections, Intra-Articular, Iopamidol, Male, Middle Aged, Prospective Studies, Radiation Dosage, Radiography, Interventional, Shoulder Joint, Time Factors, Tomography, X-Ray Computed
Pubmed
Web of science
Création de la notice
29/02/2008 18:45
Dernière modification de la notice
20/08/2019 15:24
Données d'usage