Diagnostic accuracy of bone scintigraphy in the assessment of cardiac transthyretin-related amyloidosis: a bivariate meta-analysis.
Détails
ID Serval
serval:BIB_68D1B2E7058A
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Diagnostic accuracy of bone scintigraphy in the assessment of cardiac transthyretin-related amyloidosis: a bivariate meta-analysis.
Périodique
European journal of nuclear medicine and molecular imaging
ISSN
1619-7089 (Electronic)
ISSN-L
1619-7070
Statut éditorial
Publié
Date de publication
10/2018
Peer-reviewed
Oui
Volume
45
Numéro
11
Pages
1945-1955
Langue
anglais
Notes
Publication types: Journal Article ; Meta-Analysis
Publication Status: ppublish
Publication Status: ppublish
Résumé
Cardiac transthyretin-related amyloidosis (ATTR) is a progressive and fatal cardiomyopathy. The diagnosis of this disease is frequently delayed or missed due to the limited specificity of echocardiography. An increasing amount of data in the literature demonstrate the ability of bone scintigraphy with bone-seeking radiopharmaceuticals to detect myocardial amyloid deposits, in particular in patients with ATTR. Therefore we performed a systematic review and bivariate meta-analysis of the diagnostic accuracy of bone scintigraphy in patients with suspected cardiac ATTR.
A comprehensive computer literature search of studies published up to 30 November 2017 on the role of bone scintigraphy in patients with ATTR was performed using the following search algorithm: (a) "amyloid" OR "amyloidosis" AND (b) "TTR" OR "ATTR" OR "transthyretin" AND (c) "scintigraphy" OR "scan" OR "SPECT" OR "SPET" OR "bone" OR "skeletal" OR "skeleton" OR "PYP" OR "DPD" OR "HMDP" OR "MDP" OR "HDP". Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratio (DOR) of bone scintigraphy were calculated.
The meta-analysis of six selected studies on bone scintigraphy in cardiac ATTR including 529 patients provided the following results: sensitivity 92.2% (95% CI 89-95%), specificity 95.4% (95% CI 77-99%), LR+ 7.02 (95% CI 3.42-14.4), LR- 0.09 (95% CI 0.06-0.14), and DOR 81.6 (95% CI 44-153). Mild heterogeneity was found among the selected studies.
Our evidence-based data demonstrate that bone scintigraphy using technetium-labelled radiotracers provides very high diagnostic accuracy in the non-invasive assessment of cardiac ATTR.
A comprehensive computer literature search of studies published up to 30 November 2017 on the role of bone scintigraphy in patients with ATTR was performed using the following search algorithm: (a) "amyloid" OR "amyloidosis" AND (b) "TTR" OR "ATTR" OR "transthyretin" AND (c) "scintigraphy" OR "scan" OR "SPECT" OR "SPET" OR "bone" OR "skeletal" OR "skeleton" OR "PYP" OR "DPD" OR "HMDP" OR "MDP" OR "HDP". Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratio (DOR) of bone scintigraphy were calculated.
The meta-analysis of six selected studies on bone scintigraphy in cardiac ATTR including 529 patients provided the following results: sensitivity 92.2% (95% CI 89-95%), specificity 95.4% (95% CI 77-99%), LR+ 7.02 (95% CI 3.42-14.4), LR- 0.09 (95% CI 0.06-0.14), and DOR 81.6 (95% CI 44-153). Mild heterogeneity was found among the selected studies.
Our evidence-based data demonstrate that bone scintigraphy using technetium-labelled radiotracers provides very high diagnostic accuracy in the non-invasive assessment of cardiac ATTR.
Mots-clé
Amyloid Neuropathies, Familial/diagnostic imaging, Humans, Multivariate Analysis, Radionuclide Imaging/methods, Sensitivity and Specificity, ATTR, Amyloid, Bone scintigraphy, Cardiac amyloidosis, Transthyretin
Pubmed
Web of science
Création de la notice
05/10/2018 16:30
Dernière modification de la notice
20/08/2019 14:23