One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus.

Détails

ID Serval
serval:BIB_67D554F1D55D
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus.
Périodique
American journal of ophthalmology
Auteur⸱e⸱s
Coskunseven E., Kymionis G.D., Tsiklis N.S., Atun S., Arslan E., Jankov M.R., Pallikaris I.G.
ISSN
0002-9394 (Print)
ISSN-L
0002-9394
Statut éditorial
Publié
Date de publication
05/2008
Peer-reviewed
Oui
Volume
145
Numéro
5
Pages
775-779
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
To report the results of intrastromal corneal ring segment [ICRS] (KeraRing; Mediphacos, Belo Horizonte, Brazil) implantation using a femtosecond laser (IntraLase Corp, Irvine, California, USA) in keratoconic patients.
Retrospective, noncomparative, interventional study.
Thirty-two keratoconic patients (50 eyes) who underwent ICRS insertion using a femtosecond laser for channel creation and completed at least one year of follow-up were included in this study. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, topographic findings, and adverse events were assessed.
No intraoperative complications were demonstrated in this series of patients. At the first postoperative day, segment migration to the incision site was seen in three eyes (6%; early postoperative complication). To avoid melting, we repositioned the migrated segment away from the incision site. Serious second migration was not seen and we did not need to reposition any segment again. At the last postoperative examination, there was a statistically significant reduction in the spherical equivalent refractive error compared with that observed at the examination before implantation (mean +/- standard deviation, -5.62 +/- 4.15 diopters [D; range, -23.62 to 0.50 D] to -2.49 +/- 2.68 D [range, -11.12 to 3.5 D]; P < .001). The UCVA before implantation was 20/40 or worse in 47 eyes (94%; range, counting fingers to 20/30), whereas at the last follow-up examination, 14 (28%) of 50 eyes had a UCVA of 20/40 or better (range, counting fingers to 20/25). Nine eyes (18%) maintained the preimplantation BSCVA, whereas 39 eyes (68%) experienced a BSCVA gain of one to four lines at the last follow-up examination. Only in two eyes (4%; two patients) with advanced keratoconus (stage III) was there a decrease of up to two lines. Despite this deterioration in BSCVA, the patients did not want to remove the ICRSs, because there was an increase of UCVA. No late postoperative complications were observed during the follow-up period.
ICRS (KeraRing) implantation using femtosecond laser for tunnel creation is a minimally invasive procedure for improving visual acuity (both UCVA and BSCVA) in keratoconic patients.
Mots-clé
Adolescent, Adult, Corneal Stroma/physiopathology, Corneal Stroma/surgery, Female, Follow-Up Studies, Humans, Keratoconus/physiopathology, Keratoconus/surgery, Laser Therapy/methods, Male, Polymethyl Methacrylate, Postoperative Complications, Prognosis, Prostheses and Implants, Prosthesis Implantation, Refraction, Ocular, Retrospective Studies, Tomography, Optical Coherence, Visual Acuity/physiology
Pubmed
Web of science
Création de la notice
02/10/2019 9:54
Dernière modification de la notice
06/10/2019 6:26
Données d'usage