The automatic selection of ventilation parameters during the initial phase of mechanical ventilation.

Détails

ID Serval
serval:BIB_675E1617C959
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
The automatic selection of ventilation parameters during the initial phase of mechanical ventilation.
Périodique
Intensive care medicine
Auteur⸱e⸱s
Laubscher T.P., Frutiger A., Fanconi S., Brunner J.X.
ISSN
0342-4642
Statut éditorial
Publié
Date de publication
1996
Peer-reviewed
Oui
Volume
22
Numéro
3
Pages
199-207
Langue
anglais
Notes
Publication types: Clinical Trial ; Journal Article ; Multicenter Study ; Randomized Controlled Trial - Publication Status: ppublish
Résumé
OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.
Mots-clé
Adult, Aged, Blood Gas Analysis, Child, Child, Preschool, Cross-Over Studies, Humans, Lung Volume Measurements, Middle Aged, Monitoring, Physiologic, Positive-Pressure Respiration, Prospective Studies, Respiratory Insufficiency, Therapy, Computer-Assisted
Pubmed
Web of science
Création de la notice
25/01/2008 11:07
Dernière modification de la notice
20/08/2019 15:22
Données d'usage