Predicting outcomes in persistent atrial fibrillation: the impact of surface ECG f-wave amplitude following pulmonary vein isolation.
Détails
ID Serval
serval:BIB_64C4BE318898
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Predicting outcomes in persistent atrial fibrillation: the impact of surface ECG f-wave amplitude following pulmonary vein isolation.
Périodique
Journal of interventional cardiac electrophysiology
ISSN
1572-8595 (Electronic)
ISSN-L
1383-875X
Statut éditorial
Publié
Date de publication
19/02/2025
Peer-reviewed
Oui
Pages
1-13
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: aheadofprint
Publication Status: aheadofprint
Résumé
Fibrillatory wave amplitude (fWA) on 12-lead ECG predicts the outcome of ablation in atrial fibrillation (AF). We hypothesized that changes in fWA following wide circumferential isolation of pulmonary veins (WPVI) in persistent AF (peAF) is a better predictor of ablation outcome compared to baseline fWA.
Eighty-nine patients (sustained peAF 7 ± 7 months) underwent a first-time WPVI. Sixty-second ECG signals devoid of QRST waves were recorded at baseline and at the end of the WPVI (endWPVI). fWA for each ECG lead and mean fWA (meanfWA) across the 12-lead ECG were computed. Patients with recurrence after the index WPVI underwent a redo to ensure complete PVI. The primary endpoint was long-term AF freedom OFF antiarrhythmics drugs (AADs) after one or two WPVI (SUCCESS group). The FAILURE group was defined as AF recurrence post-redo.
Over a mean follow-up of 35 ± 10 months, freedom from AF OFF AADs was achieved in 61% (SUCCESS group), while 29% had AF recurrence after redo WPVI (FAILURE group). The SUCCESS group showed significantly higher fWA values in ECG leads V <sub>1</sub> , V <sub>4</sub> , and V <sub>5</sub> at baseline (p < 0.05), as well as in leads III, aVL, aVF, and V <sub>4</sub> , and in meanfWA at endWPVI (p < 0.05) compared to the FAILURE group. A baseline mean fWA ≥ 0.044 mV or a decrease in mean fWA ≤ 11% following WPVI predicted long-term sinus rhythm restoration with a sensitivity of 81% and a specificity of 69% (p < 0.05).
Low fWA values and a significant reduction in fWA following WPVI are associated with a high risk of AF recurrence in patients with peAF.
Eighty-nine patients (sustained peAF 7 ± 7 months) underwent a first-time WPVI. Sixty-second ECG signals devoid of QRST waves were recorded at baseline and at the end of the WPVI (endWPVI). fWA for each ECG lead and mean fWA (meanfWA) across the 12-lead ECG were computed. Patients with recurrence after the index WPVI underwent a redo to ensure complete PVI. The primary endpoint was long-term AF freedom OFF antiarrhythmics drugs (AADs) after one or two WPVI (SUCCESS group). The FAILURE group was defined as AF recurrence post-redo.
Over a mean follow-up of 35 ± 10 months, freedom from AF OFF AADs was achieved in 61% (SUCCESS group), while 29% had AF recurrence after redo WPVI (FAILURE group). The SUCCESS group showed significantly higher fWA values in ECG leads V <sub>1</sub> , V <sub>4</sub> , and V <sub>5</sub> at baseline (p < 0.05), as well as in leads III, aVL, aVF, and V <sub>4</sub> , and in meanfWA at endWPVI (p < 0.05) compared to the FAILURE group. A baseline mean fWA ≥ 0.044 mV or a decrease in mean fWA ≤ 11% following WPVI predicted long-term sinus rhythm restoration with a sensitivity of 81% and a specificity of 69% (p < 0.05).
Low fWA values and a significant reduction in fWA following WPVI are associated with a high risk of AF recurrence in patients with peAF.
Mots-clé
Atrial fibrillation, F-wave amplitude, Pulmonary vein isolation, Surface electrocardiogram