Bloodstream infections related to totally implantable venous access port: What is the situation in our hospital?

Détails

Ressource 1Télécharger: BIB_6192E10304A4.P001.pdf (2196.42 [Ko])
Etat: Public
Version: Après imprimatur
ID Serval
serval:BIB_6192E10304A4
Type
Mémoire
Sous-type
(Mémoire de) maîtrise (master)
Collection
Publications
Institution
Titre
Bloodstream infections related to totally implantable venous access port: What is the situation in our hospital?
Auteur⸱e⸱s
Desgranges F.
Directeur⸱rice⸱s
Zanetti G.
Détails de l'institution
Université de Lausanne, Faculté de biologie et médecine
Statut éditorial
Acceptée
Date de publication
2012
Langue
anglais
Nombre de pages
19
Résumé
Port-a-Cath© (PAC) are totally implantable devices that offer an easy and long term access to venous circulation. They have been extensively used for intravenous therapy administration and are particularly well suited for chemotherapy in oncologic patients. Previous comparative studies have shown that these devices have the lowest catheter-related bloodstream infection rates among all intravascular access systems. However, bloodstream infection (BSI) still remains a major issue of port use and epidemiology data for PAC-associated BSI (PABSI) rates differ strongly depending on studies. Also, current literature about PABSI risk factors is scarce and sometimes controversial. Such heterogeneity may depend on type of studied population and local factors. Therefore, the aim of this study was to describe local epidemiology and risk factors for PABSI in adult patients in our tertiary- care university hospital.
We conducted a retrospective cohort study in order to describe local epidemiology. We also performed a nested case-control study to identify local risk factors of PABSI. We analyzed medical files of adult patients who had a PAC implanted between January 1st, 2008 and December 31st, 2009 and looked for PABSI occurrence before May 1st, 2011 to define cases.
Thirty nine PABSI occurred in this population with an attack rate of 5.8%. We estimated an incidence rate of 0.08/1000 PAC-days using the case-control study. PABSI causative agents were mainly Gram positive cocci (62%). We identified three predictive factors of PABSI by multivariate statistical analysis: neutropenia on outcome date (Odds Ratio [OR]: 4.05; 95% confidence interval [CI]:1.05- 15.66; p=0.042), diabetes (OR: 11.53; 95% CI: 1.07-124.70; p=0.044) and having another infection than PABSI on outcome date (OR: 6.35; 95% CI: 1.50-26.86; p=0.012). Patients suffering from acute or renal failure (OR: 4.26; 95% CI: 0.94-19.21; p=0.059) or wearing another invasive device (OR: 2.99; 95%CI:0.96-9.31; p=0.059) did not have a statistically increased risk for developing a PABSI according to classical threshold (p<0.05) but nevertheless remained close to significance.
Our study demonstrated that local epidemiology and microbiology of PABSI in our institution was similar to previous reports. A larger prospective study is required to confirm our results or to test preventive measures.
Mots-clé
port, bloodstream infection, intravascular device
Création de la notice
12/09/2013 14:31
Dernière modification de la notice
20/08/2019 15:18
Données d'usage