Acute inflammatory reaction associated with endoluminal bypass grafts.

Détails

ID Serval
serval:BIB_57378852F943
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Acute inflammatory reaction associated with endoluminal bypass grafts.
Périodique
Journal of Endovascular Surgery
Auteur⸱e⸱s
Hayoz D., Do D.D., Mahler F., Triller J., Spertini F.
ISSN
1074-6218
Statut éditorial
Publié
Date de publication
1997
Peer-reviewed
Oui
Volume
4
Numéro
4
Pages
354-360
Langue
anglais
Résumé
PURPOSE: Nonspecific inflammatory reactions characterized by local tenderness, fever, and flu-like discomfort have been seen in patients undergoing endoluminal graft placement in the abdominal aorta or the femoral arteries. We undertook a study to assess the clinical and laboratory parameters of this inflammation. METHODS: Ten patients with femoropopliteal artery (n = 9) or aortic (n = 1) lesions were treated with EndoPro System 1 stent-grafts made of nitinol alloy and covered with a polyester (Dacron) fabric. Eleven patients implanted with a bare nitinol stent served as the control group. RESULTS: In the stent-graft group, four patients showed clinical signs of acute inflammation manifested by fever and local tenderness. Three of these patients suffered thrombosis of the stent-grafts during the first month of follow-up. Plasma levels of interleukin-1 beta and interleukin-6 in all stent-graft patients were markedly increased 1 day after intervention (7.3 +/- 2.8 versus 90.2 +/- 34.1 pg/mL and 15.6 +/- 5.8 versus 175.5 +/- 66.3 pg/mL, respectively; p < 0.01). This was followed by an increase in fibrinogen (3.0 +/- 0.2 versus 5.0 +/- 0.2 g/L; p < 0.05) and C-reactive protein (14.6 +/- 3.3 versus 77.5 +/- 15.0 mg/L; p < 0.01) at 1 week. No direct correlation between the inflammatory markers and symptoms could be found. In vitro analysis showed that individual components of the stent-graft did not activate human neutrophils, whereas the intact stent-graft itself induced a marked neutrophil activation. CONCLUSIONS: The component of the self-expanding stent-graft responsible for the nonspecific inflammatory reaction was not identified in this study. It is likely that the stent-graft itself or some as yet unrecognized element of the device other than the Dacron fabric or metal alloy may be a potent in vivo inducer of cytokine reaction by neutrophils.
Mots-clé
Aged, Alloys, Aneurysm, Aorta, Abdominal, Arterial Occlusive Diseases, Blood Vessel Prosthesis, Cytokines, Enzyme-Linked Immunosorbent Assay, Female, Femoral Artery, Foreign-Body Reaction, Humans, Male, Polyesters, Postoperative Complications, Stents, Vascular Patency
Pubmed
Web of science
Création de la notice
17/01/2008 17:38
Dernière modification de la notice
20/08/2019 15:11
Données d'usage