The Effect Of Induced Intraocular Straylight (cataract Simulation) On Sensitivity Measures Of Standard Automated Perimetry, Pulsar Perimetry And Moorfields Motion Displacement Test

Détails

ID Serval
serval:BIB_51DBAF62E2F6
Type
Actes de conférence (partie): contribution originale à la littérature scientifique, publiée à l'occasion de conférences scientifiques, dans un ouvrage de compte-rendu (proceedings), ou dans l'édition spéciale d'un journal reconnu (conference proceedings).
Sous-type
Abstract (résumé de présentation): article court qui reprend les éléments essentiels présentés à l'occasion d'une conférence scientifique dans un poster ou lors d'une intervention orale.
Collection
Publications
Institution
Titre
The Effect Of Induced Intraocular Straylight (cataract Simulation) On Sensitivity Measures Of Standard Automated Perimetry, Pulsar Perimetry And Moorfields Motion Displacement Test
Titre de la conférence
ARVO E-Abstract 5518/A319
Auteur⸱e⸱s
Oleszczuk J.D., Bergin C., Sharkawi E.
Organisation
Association for Research in Vision and Ophthalmology
Adresse
Fort Lauderdale
Statut éditorial
Publié
Date de publication
2011
Peer-reviewed
Oui
Langue
anglais
Résumé
Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.
Création de la notice
21/01/2012 17:39
Dernière modification de la notice
20/08/2019 15:07
Données d'usage