Direct comparison and reproducibility of two segmentation methods for multicompartment dosimetry: round robin study on radioembolization treatment planning in hepatocellular carcinoma.

Détails

Ressource 1Télécharger: 37698645_BIB_513DEFD0D73B.pdf (1799.91 [Ko])
Etat: Public
Version: Final published version
Licence: CC BY 4.0
ID Serval
serval:BIB_513DEFD0D73B
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Direct comparison and reproducibility of two segmentation methods for multicompartment dosimetry: round robin study on radioembolization treatment planning in hepatocellular carcinoma.
Périodique
European journal of nuclear medicine and molecular imaging
Auteur⸱e⸱s
Lam M., Garin E., Palard-Novello X., Mahvash A., Kappadath C., Haste P., Tann M., Herrmann K., Barbato F., Geller B., Schaefer N., Denys A., Dreher M., Fowers K.D., Gates V., Salem R.
ISSN
1619-7089 (Electronic)
ISSN-L
1619-7070
Statut éditorial
Publié
Date de publication
12/2023
Peer-reviewed
Oui
Volume
51
Numéro
1
Pages
245-257
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Investigate reproducibility of two segmentation methods for multicompartment dosimetry, including normal tissue absorbed dose (NTAD) and tumour absorbed dose (TAD), in hepatocellular carcinoma patients treated with yttrium-90 ( <sup>90</sup> Y) glass microspheres.
TARGET was a retrospective investigation in 209 patients with < 10 tumours per lobe and at least one tumour ≥ 3 cm ± portal vein thrombosis. Dosimetry was compared using two distinct segmentation methods: anatomic (CT/MRI-based) and count threshold-based on pre-procedural <sup>99m</sup> Tc-MAA SPECT. In a round robin substudy in 20 patients with ≤ 5 unilobar tumours, the inter-observer reproducibility of eight reviewers was evaluated by computing reproducibility coefficient (RDC) of volume and absorbed dose for whole liver, whole liver normal tissue, perfused normal tissue, perfused liver, total perfused tumour, and target lesion. Intra-observer reproducibility was based on second assessments in 10 patients ≥ 2 weeks later.
<sup>99m</sup> Tc-MAA segmentation calculated higher absorbed doses compared to anatomic segmentation (n = 209), 43.9% higher for TAD (95% limits of agreement [LoA]: - 49.0%, 306.2%) and 21.3% for NTAD (95% LoA: - 67.6%, 354.0%). For the round robin substudy (n = 20), inter-observer reproducibility was better for anatomic (RDC range: 1.17 to 3.53) than <sup>99m</sup> Tc-MAA SPECT segmentation (1.29 to 7.00) and similar between anatomic imaging modalities (CT: 1.09 to 3.56; MRI: 1.24 to 3.50). Inter-observer reproducibility was better for larger volumes. Perfused normal tissue volume RDC was 1.95 by anatomic and 3.19 by <sup>99m</sup> Tc-MAA SPECT, with corresponding absorbed dose RDC 1.46 and 1.75. Total perfused tumour volume RDC was higher, 2.92 for anatomic and 7.0 by <sup>99m</sup> Tc-MAA SPECT with corresponding absorbed dose RDC of 1.84 and 2.78. Intra-observer variability was lower for perfused NTAD (range: 14.3 to 19.7 Gy) than total perfused TAD (range: 42.8 to 121.4 Gy).
Anatomic segmentation-based dosimetry, versus <sup>99m</sup> Tc-MAA segmentation, results in lower absorbed doses with superior reproducibility. Higher volume compartments, such as normal tissue versus tumour, exhibit improved reproducibility.
NCT03295006.
Mots-clé
Humans, Carcinoma, Hepatocellular/diagnostic imaging, Carcinoma, Hepatocellular/radiotherapy, Carcinoma, Hepatocellular/drug therapy, Liver Neoplasms/diagnostic imaging, Liver Neoplasms/radiotherapy, Liver Neoplasms/drug therapy, Retrospective Studies, Reproducibility of Results, Technetium Tc 99m Aggregated Albumin, Tomography, Emission-Computed, Single-Photon, Yttrium Radioisotopes/therapeutic use, Microspheres, Embolization, Therapeutic/adverse effects, Dosimetry, Hepatocellular carcinoma, Radioembolization, Yttrium-90
Pubmed
Web of science
Open Access
Oui
Création de la notice
13/09/2023 8:58
Dernière modification de la notice
08/08/2024 6:33
Données d'usage