Intraprocedural 3D Quantification of Lipiodol Deposition on Cone-Beam CT Predicts Tumor Response After Transarterial Chemoembolization in Patients with Hepatocellular Carcinoma.

Détails

Ressource 1Demande d'une copieTélécharger: BIB_4CFA1C0F625D.P001.pdf (2847.10 [Ko])
Etat: Supprimée
Version: de l'auteur⸱e
ID Serval
serval:BIB_4CFA1C0F625D
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Intraprocedural 3D Quantification of Lipiodol Deposition on Cone-Beam CT Predicts Tumor Response After Transarterial Chemoembolization in Patients with Hepatocellular Carcinoma.
Périodique
Cardiovascular and Interventional Radiology
Auteur⸱e⸱s
Wang Z., Chen R., Duran R., Zhao Y., Yenokyan G., Chapiro J., Schernthaner R., Radaelli A., Lin M., Geschwind J.F.
ISSN
1432-086X (Electronic)
ISSN-L
0174-1551
Statut éditorial
Publié
Date de publication
2015
Peer-reviewed
Oui
Volume
38
Numéro
6
Pages
1548-1556
Langue
anglais
Résumé
PURPOSE: To evaluate whether intraprocedural 3D quantification of Lipiodol deposition on cone-beam computed tomography (CBCT) can predict tumor response on follow-up contrast-enhanced magnetic resonance imaging (CE-MRI) in patients with hepatocellular carcinoma (HCC) treated with conventional transarterial chemoembolization (cTACE).
MATERIALS AND METHODS: This IRB approved, retrospective analysis included 36 patients with 51 HCC target lesions, who underwent cTACE with CBCT. CE-MRI was acquired at baseline and 1 month after cTACE. Overall tumor volumes as well as intratumoral Lipiodol volumes on CBCT were measured and compared with the overall and necrotic (non-enhancing) tumor volumes on CE-MRI using the paired student's t test. Tumor response on CE-MRI was assessed using modified response evaluation criteria in solid tumors (mRECIST). A linear regression model was used to correlate tumor volumes, Lipiodol volumes, and the percentage of Lipiodol deposition on CBCT with the corresponding parameters on CE-MRI. Nonparametric spearman rank-order correlation and trend test were used to correlate the percentage of Lipiodol deposition in the tumor with tumor response.
RESULT: A strong correlation between overall tumor volumes on CBCT and CE-MRI was observed (R(2) = 0.986). In addition, a strong correlation was obtained between the volume of Lipiodol deposition on CBCT and tumor necrosis (in cm(3)) on CE-MRI (R(2) = 0.960), and between the percentage of Lipiodol deposition and tumor necrosis (R(2) = 0.979). Importantly, the extent of Lipiodol deposition (in percentage of total tumor volume) correlated strongly with tumor response on CE-MRI (Spearman rho = 0.84, p < 0.001).
CONCLUSIONS: Intraprocedural 3D quantification of Lipiodol deposition on CBCT can be used to predict tumor response on follow-up CE-MRI.
Pubmed
Création de la notice
03/09/2015 11:04
Dernière modification de la notice
20/08/2019 15:01
Données d'usage