Effects of stereotactic arrhythmia radioablation on left ventricular ejection fraction and valve function over time.
Détails
ID Serval
serval:BIB_440E0B6F4F30
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Effects of stereotactic arrhythmia radioablation on left ventricular ejection fraction and valve function over time.
Périodique
Heart rhythm
ISSN
1556-3871 (Electronic)
ISSN-L
1547-5271
Statut éditorial
Publié
Date de publication
08/2023
Peer-reviewed
Oui
Volume
20
Numéro
8
Pages
1206-1207
Langue
anglais
Notes
Publication types: Research Support, Non-U.S. Gov't ; Letter
Publication Status: ppublish
Publication Status: ppublish
Résumé
Twenty patients (80% male) were included, 15 (75%) with a non-ischemic cardiomyopathy. The radiotherapy dose was 20Gy (20;25) prescribed to a planning target volume (PTV) of 25cc (18;39) resulting in a median whole-heart dose of 6.1Gy. The follow-up duration before and after STAR was 2.1 (0.6;4.5) and 1.7 (0.9;3.9) years respectively. The number of echocardiograms was 5 (3;7) before and 4 (2;7) after STAR.
Mots-clé
Humans, Stroke Volume, Ventricular Function, Left, Arrhythmias, Cardiac, Tachycardia, Ventricular/diagnosis, Tachycardia, Ventricular/surgery, Echocardiography, Left ventricular ejection fraction, Stereotactic arrhythmia radioablation (STAR), Valve disease, Ventricular tachycardia (VT)