Cross-validation of bioelectrical impedance analysis for the assessment of body composition in a representative sample of 6- to 13-year-old children.

Détails

ID Serval
serval:BIB_432080474504
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Cross-validation of bioelectrical impedance analysis for the assessment of body composition in a representative sample of 6- to 13-year-old children.
Périodique
European Journal of Clinical Nutrition
Auteur⸱e⸱s
Kriemler S., Puder J., Zahner L., Roth R., Braun-Fahrländer C., Bedogni G.
ISSN
1476-5640[electronic]
Statut éditorial
Publié
Date de publication
2009
Peer-reviewed
Oui
Volume
63
Numéro
5
Pages
619-626
Langue
anglais
Résumé
BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.
Mots-clé
Absorptiometry, Photon, Adipose Tissue, Adolescent, Algorithms, Anthropometry, Body Composition, Body Size, Child, Electric Impedance/diagnostic use, Female, Humans, Linear Models, Male, Reproducibility of Results, Switzerland
Pubmed
Web of science
Open Access
Oui
Création de la notice
02/02/2010 12:10
Dernière modification de la notice
20/08/2019 14:46
Données d'usage