Atrial Cardiopathy and Likely Pathogenic Patent Foramen Ovale in Embolic Stroke of Undetermined Source.

Détails

ID Serval
serval:BIB_3BEBBC397DBE
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Atrial Cardiopathy and Likely Pathogenic Patent Foramen Ovale in Embolic Stroke of Undetermined Source.
Périodique
Thrombosis and haemostasis
Auteur⸱e⸱s
Leventis I.A., Sagris D., Strambo D., Perlepe K., Sirimarco G., Nannoni S., Korompoki E., Manios E., Makaritsis K., Vemmos K., Michel P., Ntaios G.
ISSN
2567-689X (Electronic)
ISSN-L
0340-6245
Statut éditorial
Publié
Date de publication
03/2021
Peer-reviewed
Oui
Volume
121
Numéro
3
Pages
361-365
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Atrial cardiopathy and likely pathogenic patent foramen ovale (PFO) are two potential embolic sources in patients with embolic stroke of undetermined source (ESUS). The relationship between these two mechanisms among ESUS patients remains unclear.
Atrial cardiopathy was defined as increased left atrial diameter index (> 23 mm/m <sup>2</sup> ) or left atrial volume index (> 34 mL/m <sup>2</sup> ), or PR prolongation (≥ 200 ms), or presence of supraventricular extrasystoles in the electrocardiograms performed during hospitalization for the index stoke. The presence of PFO was assessed by transthoracic echocardiography with microbubble test or by transesophageal echocardiography. The presence of PFO was considered as likely pathogenic if the Risk of Paradoxical Embolism score was 7 to 10.
Among 367 ESUS patients with available information about the presence of PFO and the presence of atrial cardiopathy (median age: 61 years, 40.6% women), likely pathogenic PFO was diagnosed in 62 (16.9%) and atrial cardiopathy in 122 (33.2%). Only 4 patients (1.1%) had both likely pathogenic PFO and atrial cardiopathy. The prevalence of atrial cardiopathy was lower in patients with likely pathogenic PFO (6.5%) compared with patients with likely incidental PFO (31.2%) or without PFO (40.6%) (Pearson's chi-square test: 26.08, p < 0.001; adjusted odds ratio [OR]: 0.28, 95% confidence interval [CI]: 0.09-0.86). The prevalence of likely pathogenic PFO was lower in patients with atrial cardiopathy compared with patients without atrial cardiopathy (3.3% vs. 23.7%, respectively [Pearson's chi-square test: 24.13, p < 0.001; adjusted OR: 0.2, 95% CI: 0.02-0.6]).
The presence of atrial cardiopathy is inversely related to the presence of likely pathogenic PFO in patients with ESUS.
Pubmed
Web of science
Création de la notice
15/09/2020 10:50
Dernière modification de la notice
20/06/2021 17:32
Données d'usage