Transthoracic real-time three-dimensional echocardiography using a fan-like scanning approach for data acquisition: methods, strengths, problems, and initial clinical experience

Détails

ID Serval
serval:BIB_36E1C160ABFB
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Transthoracic real-time three-dimensional echocardiography using a fan-like scanning approach for data acquisition: methods, strengths, problems, and initial clinical experience
Périodique
Echocardiography
Auteur⸱e⸱s
Delabays  A., Pandian  N. G., Cao  Q. L., Sugeng  L., Marx  G., Ludomirski  A., Schwartz  S. L.
ISSN
0742-2822 (Print)
Statut éditorial
Publié
Date de publication
01/1995
Volume
12
Numéro
1
Pages
49-59
Notes
Journal Article
Research Support, Non-U.S. Gov't --- Old month value: Jan
Résumé
Three-dimensional echocardiography is an emerging clinical method to assess cardiovascular disorders. The feasibility of using a linear mode scanning (parallel slicing) for transthoracic data acquisition has been demonstrated. In this study, we evaluated the feasibility of real-time transthoracic three-dimensional imaging of the heart using a fan-like scanning mode of echocardiographic data acquisition. We used a computer-driven motor to sequentially angulate transthoracic transducers over a fan-like arc up to 90 degrees. With careful ECG and respiratory gating, we acquired basic two-dimensional data set via parasternal and subcostal windows and performed dynamic three-dimensional reconstructions. The problems encountered included the need to repeat data acquisition sequences because of transducer movement or inappropriate gain and gray scale settings. From 15 scanning sequences in four patients, we were able to use ten sets of data. These yielded good quality three-dimensional studies projecting normal valves, a stenotic mitral valve, and an atrial septal defect, in a number of novel views. The valves could be visualized from above and from below as well as in other orientations, and the detailed anatomy appraised. Spatial relationships of the atrial septal defect with inferior and superior vena cava, coronary sinus, or tricuspid annulus could be uniquely displayed through views from the right side of the heart. This technique provided adequate new imaging planes not available from two-dimensional echocardiography. This experience demonstrates for the first time that transthoracic three-dimensional echocardiography using a fan-like scanning mode of data acquisition is feasible, and that it provides adequate visualization of intracardiac structures in unique projections.(ABSTRACT TRUNCATED AT 250 WORDS)
Mots-clé
Adult Child Echocardiography/instrumentation/*methods Electrocardiography Feasibility Studies Heart Septal Defects, Atrial/ultrasonography Humans *Image Processing, Computer-Assisted Mitral Valve Stenosis/ultrasonography Rheumatic Heart Disease/ultrasonography
Pubmed
Web of science
Création de la notice
28/01/2008 10:48
Dernière modification de la notice
20/08/2019 14:25
Données d'usage