Biomechanical behaviour at the distal third of the femur: possible use of a medial metaphyseal plate
Détails
ID Serval
serval:BIB_36C68A709778
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Biomechanical behaviour at the distal third of the femur: possible use of a medial metaphyseal plate
Périodique
Injury
ISSN
0020-1383 (Print)
Statut éditorial
Publié
Date de publication
07/1998
Volume
29
Numéro
6
Pages
451-6
Notes
Rizzo, E
Ghisellini, F
Cordey, J
Wahl, D
Perren, S
Cannas, M
England
Injury
Injury. 1998 Jul;29(6):451-6. --- Old month value: Jul --- Old uritopublisher value: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=9813703
Ghisellini, F
Cordey, J
Wahl, D
Perren, S
Cannas, M
England
Injury
Injury. 1998 Jul;29(6):451-6. --- Old month value: Jul --- Old uritopublisher value: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=9813703
Résumé
The incidence of fractures in the distal femur is becoming more frequent and they are often associated to complex lesions with potential complications. Operative treatment is mandatory for elderly people and several methods of internal fixation with appropriate implants have been developed, generally approaching the lateral aspect of the femur. An alternative antero-medial access was proposed several years ago but the biomechanical aspects of its application must be debated. The aim of the present study is to establish if adverse biomechanical effects should be expected when the plate is affixed at the medial side of the femur metaphysis, by analysing the strain pattern of a human cadaver femur submitted to loads simulated in different experimental conditions. Application of load resulted, as expected, in tension in the lateral aspect and compression in the medial aspect of the femur diaphysis but it turned more and more toward the anterior aspect and the compression turned toward the posterior aspect when the levels measured changed from proximal to distal. The plate was next to the neutral axis and produced a moderate stress protection effect (approx. 70 per cent). No biomechanical disadvantages have been observed as a result of the plate being apposed at the medial aspect instead of the conventional lateral aspect of the distal femur.
Mots-clé
Aged
Aged, 80 and over
Biomechanics
*Bone Plates
Female
Femoral Fractures/*surgery
Femur/*surgery
Fracture Fixation, Internal/*methods
Humans
Stress, Mechanical
Pubmed
Web of science
Création de la notice
08/07/2008 12:03
Dernière modification de la notice
20/08/2019 14:24