One of the most difficult biliary drainages is the recurrence and stenosis on afferent loop after surgery. We report an original case of hepaticogastrostomy (HGE) in a patient who had malignant stenosis of afferent loop after cephalic duodenopancreatectomy (CDP). After failure of the gastrointestinal stent, two metal self-expandable stents were placed by endoscopic ultrasound (EUS) after puncture of the dilated left hepatic duct. On clinical improvement and disappearance of jaundice, palliative chemotherapy was started.