Augmented Cooper test: Biomechanical contributions to endurance performance.

Détails

ID Serval
serval:BIB_310D00947520
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Augmented Cooper test: Biomechanical contributions to endurance performance.
Périodique
Frontiers in sports and active living
Auteur⸱e⸱s
Apte S., Troxler S., Besson C., Gremeaux V., Aminian K.
ISSN
2624-9367 (Electronic)
ISSN-L
2624-9367
Statut éditorial
Publié
Date de publication
2022
Peer-reviewed
Oui
Volume
4
Pages
935272
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: epublish
Résumé
Running mechanics are modifiable with training and adopting an economical running technique can improve running economy and hence performance. While field measurement of running economy is cumbersome, running mechanics can be assessed accurately and conveniently using wearable inertial measurement units (IMUs). In this work, we extended this wearables-based approach to the Cooper test, by assessing the relative contribution of running biomechanics to the endurance performance. Furthermore, we explored different methods of estimating the distance covered in the Cooper test using a wearable global navigation satellite system (GNSS) receiver. Thirty-three runners (18 highly trained and 15 recreational) performed an incremental laboratory treadmill test to measure their maximum aerobic speed (MAS) and speed at the second ventilatory threshold (sVT2). They completed a 12-minute Cooper running test with foot-worm IMUs and a chest-worn GNSS-IMU on a running track 1-2 weeks later. Using the GNSS receiver, an accurate estimation of the 12-minute distance was obtained (accuracy of 16.5 m and precision of 1.1%). Using this distance, we showed a reliable estimation [R <sup>2</sup> > 0.9, RMSE ϵ (0.07, 0.25) km/h] of the MAS and sVT2. Biomechanical metrics were extracted using validated algorithm and their association with endurance performance was estimated. Additionally, the high-/low-performance runners were compared using pairwise statistical testing. All performance variables, MAS, sVT2, and average speed during Cooper test, were predicted with an acceptable error (R <sup>2</sup> ≥ 0.65, RMSE ≤ 1.80 kmh <sup>-1</sup> ) using only the biomechanical metrics. The most relevant metrics were used to develop a biomechanical profile representing the running technique and its temporal evolution with acute fatigue, identifying different profiles for runners with highest and lowest endurance performance. This profile could potentially be used in standardized functional capacity measurements to improve personalization of training and rehabilitation programs.
Mots-clé
acute fatigue, biomechanical profile, continuous assessment, running distance, wearable sensors
Pubmed
Web of science
Open Access
Oui
Création de la notice
11/10/2022 13:12
Dernière modification de la notice
18/11/2023 8:09
Données d'usage