Ureteral stents: exchange under fluoroscopic control as an effective alternative to cystoscopy.

Détails

ID Serval
serval:BIB_28D0F3EC7ED5
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Ureteral stents: exchange under fluoroscopic control as an effective alternative to cystoscopy.
Périodique
Radiology
Auteur⸱e⸱s
de Baere T., Denys A., Pappas P., Challier E., Roche A.
ISSN
0033-8419[print], 0033-8419[linking]
Statut éditorial
Publié
Date de publication
1994
Volume
190
Numéro
3
Pages
887-889
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
From September 1991 to February 1993, in 83 patients (74 women and nine men, aged 24-86 years), 166 double-J ureteral stents (initially placed to treat fistulas or stenoses located within the inferior third of the ureter) were exchanged during 127 procedures. Stents were extracted from the bladder through the urethra under fluoroscopic monitoring by using a lasso made of a 0.018-inch guide wire and a 7-F catheter. Then a new stent was placed over a 0.035-inch guide wire that had been previously coiled in the renal pelvis. Exchange was successful in 161 (97%) of 165 stents.
Mots-clé
Adult, Aged, Aged, 80 and over, Cystoscopy, Female, Fluoroscopy, Humans, Male, Middle Aged, Radiology, Interventional/methods, Stents, Ureter, Ureteral Diseases/therapy, Ureteral Obstruction/therapy, Urinary Fistula/therapy
Pubmed
Web of science
Création de la notice
17/03/2010 11:40
Dernière modification de la notice
20/08/2019 14:08
Données d'usage