Measurement of plasma D-dimer is not useful in the prediction or diagnosis of postoperative deep vein thrombosis in patients undergoing total knee arthroplasty

Détails

ID Serval
serval:BIB_264B9DFCA74A
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Measurement of plasma D-dimer is not useful in the prediction or diagnosis of postoperative deep vein thrombosis in patients undergoing total knee arthroplasty
Périodique
Blood Coagulation and Fibrinolysis
Auteur⸱e⸱s
Bounameaux  H., Miron  M. J., Blanchard  J., de Moerloose  P., Hoffmeyer  P., Leyvraz  P. F.
ISSN
0957-5235 (Print)
Statut éditorial
Publié
Date de publication
11/1998
Volume
9
Numéro
8
Pages
749-52
Notes
Clinical Trial
Journal Article
Randomized Controlled Trial --- Old month value: Nov
Résumé
Plasma D-dimer, a highly sensitive marker of venous thromboembolism, was measured using an enzyme-linked immunosorbent assay pre-operatively, on the third postoperative day, and at the time of phlebography in 118 patients undergoing elective total knee arthroplasty. Deep venous thrombosis (DVT) was detected using systematic bilateral phlebography between the eighth and 12th postoperative day in 47 (39.8%) patients. D-dimer plasma concentrations did not differ between patients who had DVT and those who had no DVT, either pre-operatively (n = 118, P = 0.63) or at the time of phlebography (n = 111, P = 0.70). On the third postoperative day, D-dimer concentration was significantly higher (P < 0.01) in the patients who had DVT (median 3270 microg/l, range 1156-9996, n = 47) than in those who did not (2287 microg/l, 685-7062, n = 64). However, receiver operating characteristics curve analysis did not provide any useful cutoff values that would allow individual diagnoses to be made. In conclusion, the results of the present study suggest that plasma measurement of D-dimer concentration is of no value for predicting, diagnosing or ruling out DVT in patients undergoing total knee arthroplasty.
Mots-clé
*Arthroplasty, Replacement, Knee Biological Markers/blood Confidence Intervals Enzyme-Linked Immunosorbent Assay Fibrin Fibrinogen Degradation Products/*analysis Humans Phlebography Postoperative Complications/blood/*diagnosis/prevention & control Predictive Value of Tests ROC Curve Sensitivity and Specificity Statistics, Nonparametric Thrombophlebitis/blood/*diagnosis/prevention & control