The development of decision limits for the GH-2000 detection methodology using additional insulin-like growth factor-I and amino-terminal pro-peptide of type III collagen assays.

Détails

ID Serval
serval:BIB_24BA2249022C
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
The development of decision limits for the GH-2000 detection methodology using additional insulin-like growth factor-I and amino-terminal pro-peptide of type III collagen assays.
Périodique
Drug Testing and Analysis
Auteur⸱e⸱s
Holt R.I., Böhning W., Guha N., Bartlett C., Cowan D.A., Giraud S., Bassett E.E., Sönksen P.H., Böhning D.
ISSN
1942-7611 (Electronic)
ISSN-L
1942-7603
Statut éditorial
Publié
Date de publication
2015
Peer-reviewed
Oui
Volume
7
Numéro
9
Pages
745-755
Langue
anglais
Notes
Publication types: Evaluation Studies ; Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
The GH-2000 and GH-2004 projects have developed a method for detecting GH misuse based on measuring insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objectives were to analyze more samples from elite athletes to improve the reliability of the decision limit estimates, to evaluate whether the existing decision limits needed revision, and to validate further non-radioisotopic assays for these markers. The study included 998 male and 931 female elite athletes. Blood samples were collected according to World Anti-Doping Agency (WADA) guidelines at various sporting events including the 2011 International Association of Athletics Federations (IAAF) World Athletics Championships in Daegu, South Korea. IGF-I was measured by the Immunotech A15729 IGF-I IRMA, the Immunodiagnostic Systems iSYS IGF-I assay and a recently developed mass spectrometry (LC-MS/MS) method. P-III-NP was measured by the Cisbio RIA-gnost P-III-P, Orion UniQ™ PIIINP RIA and Siemens ADVIA Centaur P-III-NP assays. The GH-2000 score decision limits were developed using existing statistical techniques. Decision limits were determined using a specificity of 99.99% and an allowance for uncertainty because of the finite sample size. The revised Immunotech IGF-I - Orion P-III-NP assay combination decision limit did not change significantly following the addition of the new samples. The new decision limits are applied to currently available non-radioisotopic assays to measure IGF-I and P-III-NP in elite athletes, which should allow wider flexibility to implement the GH-2000 marker test for GH misuse while providing some resilience against manufacturer withdrawal or change of assays.
Mots-clé
Adolescent, Adult, Athletes, Child, Doping in Sports, Female, Human Growth Hormone/blood, Humans, Immunoassay/methods, Insulin-Like Growth Factor I/analysis, Limit of Detection, Male, Peptide Fragments/blood, Procollagen/blood, Substance Abuse Detection/methods, Tandem Mass Spectrometry/methods, Young Adult
Pubmed
Web of science
Création de la notice
29/09/2015 17:30
Dernière modification de la notice
20/08/2019 14:03
Données d'usage