Continuous monitoring of liver oxygenation with near infrared spectroscopy during naso-gastric tube feeding in neonates.

Détails

ID Serval
serval:BIB_22FFFAAC688C
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Continuous monitoring of liver oxygenation with near infrared spectroscopy during naso-gastric tube feeding in neonates.
Périodique
Schweizerische medizinische Wochenschrift
Auteur⸱e⸱s
Teller J., Schwendener K., Wolf M., Keel M., Bucher H.U., Fanconi S., Baenziger O.
ISSN
0036-7672
Statut éditorial
Publié
Date de publication
2000
Peer-reviewed
Oui
Volume
130
Numéro
18
Pages
652-6
Langue
anglais
Notes
Publication types: Journal Article - Publication Status: ppublish
Résumé
Near infrared spectroscopy (NIRS) is a non-invasive method of estimating the haemoglobin concentration changes in certain tissues. It is frequently used to monitor oxygenation of the brain in neonates. At present it is not clear whether near infrared spectroscopy of other organs (e.g. the liver as a corresponding site in the splanchnic region, which reacts very sensitively to haemodynamic instability) provides reliable values on their tissue oxygenation. The aim of the study was to test near infrared spectroscopy by measuring known physiologic changes in tissue oxygenation of the liver in newborn infants during and after feeding via a naso-gastric tube. The test-retest variability of such measurements was also determined. On 28 occasions in 25 infants we measured the tissue oxygenation index (TOI) of the liver and the brain continuously before, during and 30 minutes after feeding via a gastric tube. Simultaneously we measured arterial oxygen saturation (SaO2), heart rate (HR) and mean arterial blood pressure (MAP). In 10 other newborn infants we performed a test-retest analysis of the liver tissue oxygenation index to estimate the variability in repeated intra-individual measurements. The tissue oxygenation index of the liver increased significantly from 56.7 +/- 7.5% before to 60.3 +/- 5.6% after feeding (p < 0.005), and remained unchanged for the next 30 minutes. The tissue oxygenation index of the brain (62.1 +/- 9.7%), SaO2 (94.4 +/- 7.1%), heart rate (145 +/- 17.3 min-1) and mean arterial blood pressure (52.8 +/- 10.2 mm Hg) did not change significantly. The test-retest variability for intra-individual measurements was 2.7 +/- 2.1%. After bolus feeding the tissue oxygenation index of the liver increased as expected. This indicates that near infrared spectroscopy is suitable for monitoring changes in tissue oxygenation of the liver in newborn infants.
Mots-clé
Blood Pressure, Enteral Nutrition, Female, Gestational Age, Heart Rate, Humans, Infant, Newborn, Infant, Premature, Intubation, Gastrointestinal, Liver, Male, Monitoring, Physiologic, Oxygen, Oxygen Consumption, Reproducibility of Results, Spectrophotometry, Infrared
Pubmed
Web of science
Création de la notice
25/01/2008 11:06
Dernière modification de la notice
20/08/2019 14:00
Données d'usage