Quantification of dose nonuniformities by voxel-based dosimetry in patients receiving 90Y-ibritumomab-tiuxetan.

Détails

Ressource 1Télécharger: BIB_20BD877D62C1.P001.pdf (496.38 [Ko])
Etat: Public
Version: Final published version
ID Serval
serval:BIB_20BD877D62C1
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Quantification of dose nonuniformities by voxel-based dosimetry in patients receiving 90Y-ibritumomab-tiuxetan.
Périodique
Cancer Biotherapy and Radiopharmaceuticals
Auteur⸱e⸱s
Cicone F., D'Arienzo M., Carpaneto A., Russo E., Coniglio A., Delaloye A.B., Scopinaro F.
ISSN
1557-8852 (Electronic)
ISSN-L
1084-9785
Statut éditorial
Publié
Date de publication
2013
Volume
28
Numéro
2
Pages
98-107
Langue
anglais
Notes
Publication types: Journal ArticlePublication Status: ppublish. PDF type: Original Article
Résumé
OBJECTIVE: To assess the impact of nonuniform dose distribution within lesions and tumor-involved organs of patients receiving Zevalin, and to discuss possible implications of equivalent uniform biological effective doses (EU-BED) on treatment efficacy and toxicity. MATLAB? -based software for voxel-based dosimetry was adopted for this purpose.
METHODS: Eleven lesions from seven patients with either indolent or aggressive non-Hodgkin lymphoma were analyzed, along with four organs with disease. Absorbed doses were estimated by a direct integration of single-voxel kinetic data from serial tomographic images. After proper corrections, differential BED distributions and surviving cell fractions were estimated, allowing for the calculation of EU-BED. To quantify dose uniformity in each target area, a heterogeneity index was defined.
RESULTS: Average doses were below those prescribed by conventional radiotherapy to eradicate lymphoma lesions. Dose heterogeneity and effect on tumor control varied among lesions, with no apparent relation to tumor mass. Although radiation doses to involved organs were safe, unexpected liver toxicity occurred in one patient who presented with a pattern of diffuse infiltration.
CONCLUSION: Voxel-based dosimetry and radiobiologic modeling can be successfully applied to lesions and tumor-involved organs, representing a methodological advance over estimation of mean absorbed doses. However, effects on tumor control and organ toxicity still cannot be easily predicted.
Pubmed
Web of science
Open Access
Oui
Création de la notice
12/04/2013 18:35
Dernière modification de la notice
20/08/2019 13:57
Données d'usage