Combined Collection and Analysis of Inorganic and Organic Gunshot Residues.

Détails

Ressource 1Télécharger: RedouteMinziere_Werner_et_al_2020_Serval.pdf (904.06 [Ko])
Etat: Public
Version: de l'auteur⸱e
Licence: Non spécifiée
ID Serval
serval:BIB_20A7C79BB124
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Combined Collection and Analysis of Inorganic and Organic Gunshot Residues.
Périodique
Journal of forensic sciences
Auteur⸱e⸱s
Redouté Minzière V., Werner D., Schneider D., Manganelli M., Jung B., Weyermann C., Gassner A.L.
ISSN
1556-4029 (Electronic)
ISSN-L
0022-1198
Statut éditorial
Publié
Date de publication
07/2020
Peer-reviewed
Oui
Volume
65
Numéro
4
Pages
1102-1113
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Gunshot residue (GSR) analysis and their interpretation provide crucial information on a criminal investigation involving the use of firearms. To date, several approaches have been proposed for the implementation of a combined sampling and analysis of inorganic (IGSR) and organic GSR (OGSR). However, it is not clear at this stage if concurrent analyses of both types of residue might be detrimental to the analysis of IGSR currently applied in forensic laboratories. Thus, this work aims to compare and evaluate three different protocols for the combined collection and analysis of IGSR and OGSR. These methods, respectively, involve the use of a modified stub (with two halves, one for the detection of IGSR and the other for the analysis of OGSR); the sequential recovery of GSR with two stubs mounted with different adhesives (double-sided carbon tape and Tesa® TACK) and the sequential analysis of IGSR and OGSR from a single carbon stub following carbon deposition. The detection of IGSR was carried out using SEM-EDX, while OGSR analysis was performed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Obtained results for experiments performed using Geco Sinoxid <sup>®</sup> ammunition indicated that sequential analysis was the most suitable protocol for the combined collection and analysis of both IGSR and OGSR. A higher number of inorganic (characteristic and consistent) particles and higher concentrations of ethylcentralite, N-nitrosodiphenylamine, diphenylamine, and nitroglycerin were recovered with this method.
Mots-clé
firearm discharge residue, inorganic gunshot residues, organic gunshot residues, scanning electron microscopy–energy-disper-sive x-ray spectroscopy (SEM-EDX), liquid chromatography, mass spectrometry, scanning electron microscopy-energy-dispersive x-ray spectroscopy (SEM-EDX)
Pubmed
Web of science
Open Access
Oui
Financement(s)
Fonds national suisse / 10521A_165608
Fonds national suisse / 105211_188898
Création de la notice
23/03/2020 11:04
Dernière modification de la notice
21/11/2022 9:21