Multicentre evaluation of 5B9, a monoclonal anti-PF4/heparin IgG mimicking human HIT antibodies, as an internal quality control in HIT functional assays: Communication from the ISTH SSC Subcommittee on Platelet Immunology.

Détails

ID Serval
serval:BIB_19F6FEB89077
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Multicentre evaluation of 5B9, a monoclonal anti-PF4/heparin IgG mimicking human HIT antibodies, as an internal quality control in HIT functional assays: Communication from the ISTH SSC Subcommittee on Platelet Immunology.
Périodique
Journal of thrombosis and haemostasis
Auteur⸱e⸱s
Pouplard C., Rollin J., Vayne C., Charuel N., Ahmadi Z., Alberio L., Azjenberg N., Althaus K., Bakchoul T., Chong B., Curtis B.R., Faille D., Gomez F.J., Gresele P., Morel-Kopp M.C., Mullier F., Nazy I., Smith J.W., Greinacher A., Gruel Y.
ISSN
1538-7836 (Electronic)
ISSN-L
1538-7836
Statut éditorial
Publié
Date de publication
01/2022
Peer-reviewed
Oui
Volume
20
Numéro
1
Pages
252-259
Langue
anglais
Notes
Publication types: Journal Article ; Multicenter Study ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
Functional tests for the diagnosis of heparin-induced thrombocytopenia (HIT) exhibit variable performance.
We evaluated in a multicenter study whether 5B9, a monoclonal anti-PF4/heparin IgG mimicking human HIT antibodies, could be used as an internal quality control.
5B9 was sent to 11 laboratories in seven countries, and six initial concentrations ranging from 10 to 400 μg/mL were tested by heparin-induced platelet activation assay (HIPA), serotonin release assay (SRA), platelet aggregation test (PAT), flow cytometry (FC), or heparin-induced multiple-electrode aggregometry (HIMEA). Each method was evaluated in three different laboratories using experimental procedures identical to those usually applied for the diagnosis of HIT by testing platelets from 10 different healthy donors.
The procedures used varied among the laboratories, particularly when platelet-rich plasma and whole blood were used. Nevertheless, positive results were obtained with at least 100 μg/ml of 5B9 for most donors tested by all centers (except one) performing HIPA, SRA, or HIMEA. FC and PAT results were more heterogeneous. FC results from one center that used washed platelets preincubated with PF4 were positive with all donors at 50 µg/ml 5B9, but at least 200 μg/ml of 5B9 were required to activate cells with most donors tested using PAT.
This study confirms that HIT functional tests are not well standardized and exhibit variable sensitivity for the detection of platelet-activating antibodies. However, 5B9 is a potentially useful tool to standardize functional tests, to select responding platelet donors, and consequently to improve the performance of these assays and comparability between laboratories.
Mots-clé
Antibodies, Monoclonal, Anticoagulants/adverse effects, Blood Platelets, Communication, Heparin/adverse effects, Humans, Immunoglobulin G, Platelet Activation, Platelet Factor 4, Quality Control, Thrombocytopenia/chemically induced, Thrombocytopenia/diagnosis, functional assays, heparin-induced thrombocytopenia, monoclonal antibody, platelet factor 4, standardization
Pubmed
Web of science
Création de la notice
25/10/2021 9:37
Dernière modification de la notice
09/04/2022 6:33
Données d'usage