Generation of a Recombinant Gag Virus-Like-Particle Panel for the Evaluation of p24 Antigen Detection by Diagnostic HIV Tests.

Détails

Ressource 1Télécharger: BIB_1781BD45F2A9.P001.pdf (913.31 [Ko])
Etat: Public
Version: de l'auteur⸱e
ID Serval
serval:BIB_1781BD45F2A9
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Generation of a Recombinant Gag Virus-Like-Particle Panel for the Evaluation of p24 Antigen Detection by Diagnostic HIV Tests.
Périodique
Plos One
Auteur⸱e⸱s
Vetter B.N., Orlowski V., Fransen K., Niederhauser C., Aubert V., Brandenberger M., Ciardo D., Dollenmaier G., Klimkait T., Regenass S., Schmid P., Schottstedt V., Suter-Riniker F., Yerly S., Shah C., Böni J., Schüpbach J.
ISSN
1932-6203 (Electronic)
ISSN-L
1932-6203
Statut éditorial
Publié
Date de publication
2014
Volume
9
Numéro
10
Pages
e111552
Langue
anglais
Notes
Publication types: Journal Article Publication Status: epublish
Résumé
BACKGROUND: Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens.
METHODS: We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection.
RESULTS: Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection.
CONCLUSIONS: The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.
Pubmed
Web of science
Open Access
Oui
Création de la notice
09/11/2014 16:56
Dernière modification de la notice
20/08/2019 13:47
Données d'usage