Segmental bioelectrical impedance analysis to assess perioperative fluid changes.

Détails

ID Serval
serval:BIB_120077987FB0
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Segmental bioelectrical impedance analysis to assess perioperative fluid changes.
Périodique
Critical Care Medicine
Auteur⸱e⸱s
Bracco D., Berger M.M., Revelly J.P., Schütz Y., Frascarolo P., Chioléro R.
ISSN
0090-3493 (Print)
ISSN-L
0090-3493
Statut éditorial
Publié
Date de publication
07/2000
Volume
28
Numéro
7
Pages
2390-2396
Langue
anglais
Notes
Publication types: Comparative Study ; Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
OBJECTIVES: Perioperative fluid accumulation determination is a challenge for the clinician. Bioelectrical impedance analysis (BIA) is a noninvasive method based on the electrical properties of tissues, which can assess body fluid compartments. The study aimed at assessing their changes in three types of surgery (thoracic, abdominal, and intracranial) requiring various regimens of fluid administration.
DESIGN: Prospective descriptive trial.
PATIENTS: A total of 26 patients scheduled for elective surgery were separated into three groups according to site of surgery: thoracic (n = 8), abdominal aortic (n = 8), and brain surgery (n = 10).
SETTING: University teaching hospital.
INTERVENTION: None.
MEASUREMENTS: Whole body, segmental (arm, trunk, and legs) BIA at multiple frequency (0.5, 50, 100 kHz) was used to assess perioperative fluid accumulation after surgery. The fluid balances were calculated from the charts.
RESULTS: The patients were aged 62+/-4 yrs. Fluid balances were 4.8+/-1.0 L, 4.1+/-0.5 L, and 1.9+/-0.3 L, respectively, in the three groups. In trunk surgery patients, fluid accumulation was detected as a drop in impedance in the operated area at all frequencies. In the operated area, there was an expansion of both intra- and extracellular compartments. A reduction in high frequencies' impedance in the legs was only detected after aortic surgery. Fluid accumulation and trunk impedance changes were strongly correlated. Neurosurgery only induced minor body fluid changes.
CONCLUSIONS: Segmental BIA is able to detect and localize perioperative fluid accumulation. It may become a bedside tool to quantify and to localize fluid accumulation.
Mots-clé
Abdomen/surgery, Aged, Body Composition, Brain/surgery, Electric Impedance, Female, Humans, Intraoperative Period, Male, Middle Aged, Postoperative Period, Prospective Studies, Thorax, Water-Electrolyte Balance
Pubmed
Web of science
Création de la notice
21/01/2008 14:09
Dernière modification de la notice
20/08/2019 13:39
Données d'usage