Evaluation of the BD Phoenix™ CPO Detect Test for the detection of carbapenemase producers.

Détails

Ressource 1Télécharger: CMI.pdf (524.57 [Ko])
Etat: Public
Version: Author's accepted manuscript
Licence: CC BY-NC-ND 4.0
ID Serval
serval:BIB_10B221FFC8D5
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Evaluation of the BD Phoenix™ CPO Detect Test for the detection of carbapenemase producers.
Périodique
Clinical microbiology and infection
Auteur⸱e⸱s
Croxatto A., Coste A.T., Pillonel T., Bertelli C., Greub G., Prod'hom G.
ISSN
1469-0691 (Electronic)
ISSN-L
1198-743X
Statut éditorial
Publié
Date de publication
05/2020
Peer-reviewed
Oui
Volume
26
Numéro
5
Pages
644.e9-644.e15
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Becton-Dickinson recently developed the Phoenix™ CPO (carbapenemase-producing organism) Detect Test, a growth-based test embedded in Gram-negative (GN) panels for the detection and confirmation of bacteria producing class A, B and D carbapenemases. This study aimed to (a) determine the performance of the CPO test, and (b) assess its added value in routine diagnostic workflows.
The performance of the BD Phoenix CPO test was analysed retrospectively on a collection of 185 molecularly characterized strains, including 92 CPOs, and prospectively on 135 and 160 routine isolates with and without CPO suspicion, respectively.
In the retrospective study the CPO test exhibited 92.4% accuracy (95%CI 87.6-95.8), 97.8% sensitivity (95%CI 92.4-99.7) and 87.1% specificity (95%CI 78.6-93.2) for carbapenemase detection. The CPO test provided a classification to class A, B, and D for 81.3% of detected carbapenemases with 94.6% accuracy (95%CI 86.7-98.5). In the prospective study the CPO test detection performance showed 77.8% accuracy (95%CI 68.8-84.5), 100% sensitivity (95%CI 91.2-100) and 67.8% specificity (95%CI 57.3-77.1) with 135 CPO-suspicious isolates and 98.8% accuracy and specificity (95%CI 95.6-99.9) with 160 non-CPO-suspicious isolates. Compared to routine testing, the implementation of the CPO test allowed a mean reduction of 21.3 h (95%CI 17.6-25) in turnaround time, 16.8 min (95%CI 13.4-20.2) in hands-on time, and 20.6 CHF (95%CI 16.5-24.8) in costs.
The CPO test is reliable for the detection of CPO with a high sensitivity. However, the relatively low detection specificity required the use of additional confirmatory methods. The carbapenemase classification accuracy is robust in providing preliminary results before molecular characterization. Finally, the implementation of the test in routine workflows allowed a significant reduction in turnaround time, hands-on time and cost compared to the conventional approach.
Mots-clé
CPO, Carbapenemase, Phoenix, classification, detection, test, Classification, Detection, Test
Pubmed
Web of science
Open Access
Oui
Création de la notice
24/10/2019 15:38
Dernière modification de la notice
21/11/2022 8:26
Données d'usage