Swiss Validation of the Enhanced Recovery After Surgery (ERAS) Database.
Détails
Télécharger: 33486583_BIB_0F9350EEC0A4.pdf (315.83 [Ko])
Etat: Public
Version: Final published version
Licence: CC BY 4.0
Etat: Public
Version: Final published version
Licence: CC BY 4.0
ID Serval
serval:BIB_0F9350EEC0A4
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Swiss Validation of the Enhanced Recovery After Surgery (ERAS) Database.
Périodique
World journal of surgery
ISSN
1432-2323 (Electronic)
ISSN-L
0364-2313
Statut éditorial
Publié
Date de publication
04/2021
Peer-reviewed
Oui
Volume
45
Numéro
4
Pages
940-945
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Publication Status: ppublish
Résumé
Enhanced recovery after surgery (ERAS) pathways have considerably improved postoperative outcomes and are in use for various types of surgery. The prospective audit system (EIAS) could be a powerful tool for large-scale outcome research but its database has not been validated yet.
Swiss ERAS centers were invited to contribute to the validation of the Swiss chapter for colorectal surgery. A monitoring team performed on-site visits by the use of a standardized checklist. Validation criteria were (I) coverage (No. of operated patients within ERAS protocol; target threshold for validation: ≥ 80%), (II) missing data (8 predefined variables; target ≤ 10%), and (III) accuracy (2 predefined variables, target ≥ 80%). These criteria were assessed by comparing EIAS entries with the medical charts of a random sample of patients per center (range 15-20).
Out of 18 Swiss ERAS centers, 15 agreed to have onsite monitoring but 13 granted access to the final dataset. ERAS coverage was available in only 7 centers and varied between 76 and 100%. Overall missing data rate was 5.7% and concerned mainly the variables "urinary catheter removal" (16.4%) and "mobilization on day 1" (16%). Accuracy for the length of hospital stay and complications was overall 84.6%. Overall, 5 over 13 centers failed in the validation process for one or several criteria.
EIAS was validated in most Swiss ERAS centers. Potential patient selection and missing data remain sources of bias in non-validated centers. Therefore, simplified validation of other centers appears to be mandatory before large-scale use of the EIAS dataset.
Swiss ERAS centers were invited to contribute to the validation of the Swiss chapter for colorectal surgery. A monitoring team performed on-site visits by the use of a standardized checklist. Validation criteria were (I) coverage (No. of operated patients within ERAS protocol; target threshold for validation: ≥ 80%), (II) missing data (8 predefined variables; target ≤ 10%), and (III) accuracy (2 predefined variables, target ≥ 80%). These criteria were assessed by comparing EIAS entries with the medical charts of a random sample of patients per center (range 15-20).
Out of 18 Swiss ERAS centers, 15 agreed to have onsite monitoring but 13 granted access to the final dataset. ERAS coverage was available in only 7 centers and varied between 76 and 100%. Overall missing data rate was 5.7% and concerned mainly the variables "urinary catheter removal" (16.4%) and "mobilization on day 1" (16%). Accuracy for the length of hospital stay and complications was overall 84.6%. Overall, 5 over 13 centers failed in the validation process for one or several criteria.
EIAS was validated in most Swiss ERAS centers. Potential patient selection and missing data remain sources of bias in non-validated centers. Therefore, simplified validation of other centers appears to be mandatory before large-scale use of the EIAS dataset.
Mots-clé