Does the 'oxygen cost diagram' reflect changes in six minute walking distance in follow up studies?

Détails

ID Serval
serval:BIB_0BD00E192A1A
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Does the 'oxygen cost diagram' reflect changes in six minute walking distance in follow up studies?
Périodique
Respiratory Medicine
Auteur⸱e⸱s
Janssens  J. P., Breitenstein  E., Rochat  T., Fitting  J. W.
ISSN
0954-6111 (Print)
Statut éditorial
Publié
Date de publication
11/1999
Volume
93
Numéro
11
Pages
810-5
Notes
Journal Article --- Old month value: Nov
Résumé
The oxygen cost diagram (OCD) is a simple scale for quantifying a patient's evaluation of his tolerance to exercise frequently used in clinical trials; it has been shown to be well correlated with objective measures of capacity of ambulation such as the 6 min walk test (6' W). This study aimed to determine whether the OCD accurately depicts changes in capacity of ambulation either quantitatively or qualitatively. OCD ratings were analysed at baseline and after a 1 yr follow-up, in patients treated by non-invasive home mechanical ventilation, as well as objective measurements of pulmonary function [forced expiratory volume in 1 sec (FEV1), forced vital capacity (FVC), arterial blood gases], physical autonomy (6' W), resting dyspnoea (Borg scale) and scores for anxiety or depressive disorders (HAD). Forty-five patients (24 male, 21 female, aged 62 +/- 16 years, mean FEV1: 38 +/- 17% of predicted) were evaluated at baseline. OCD ratings were significantly correlated with 6 min walking distance (P < 0.0001)--although with a large variability around the regression line--but not with resting dyspnoea (Borg). Patients were re-evaluated after 352 +/- 90 days. Changes in OCD ratings were not significantly correlated with changes in FFV1 FVC, PaO2, PaCO2, 6' W, HAD scores or resting dyspnoea; furthermore--albeit for Borg scores--changes in OCD did not reflect the trend of changes in these parameters. These results show that although OCD ratings are well correlated with results of a 6' W test, they cannot be used to extrapolate individual performances, because of a large variability around the regression line, furthermore, changes in the OCD over 1 yr did not depict objective changes in 6' W test results, either quantitatively or qualitatively. The use of the OCD in clinical trials should be limited to the description of the patient's perception of exercise tolerance, as a component of health-related quality of life, with the awareness of possible discrepancies between changes in objective performances and changes in OCD ratings.
Mots-clé
*Activities of Daily Living Adult Aged Dyspnea/physiopathology Exercise Tolerance/*physiology Female Follow-Up Studies *Health Status Indicators Home Care Services Humans Male Middle Aged Prospective Studies Quality of Life Reproducibility of Results Respiration, Artificial Respiratory Function Tests Respiratory Insufficiency/*physiopathology Walking/*physiology
Pubmed
Web of science
Open Access
Oui
Création de la notice
25/01/2008 10:43
Dernière modification de la notice
20/08/2019 13:33
Données d'usage