Collateral flow measurement by phase-contrast magnetic resonance imaging for the assessment of systemic venous baffle patency after atrial switch repair for transposition of the great arteries.

Détails

ID Serval
serval:BIB_061A514D3D55
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Collateral flow measurement by phase-contrast magnetic resonance imaging for the assessment of systemic venous baffle patency after atrial switch repair for transposition of the great arteries.
Périodique
Journal of thoracic imaging
Auteur⸱e⸱s
Muzzarelli S., Ordovas K.G., Higgins C.B., Meadows A.K.
ISSN
1536-0237 (Electronic)
ISSN-L
0883-5993
Statut éditorial
Publié
Date de publication
05/2012
Peer-reviewed
Oui
Volume
27
Numéro
3
Pages
175-178
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
We aimed to describe and compare azygos vein flow patterns of patients with obstructed and unobstructed systemic venous baffle after atrial switch repair for d-transposition of the great arteries (TGA). We hypothesized that phase-contrast magnetic resonance imaging would enable characterization of retrograde collateral flow across the azygos vein in cases of systemic venous baffle obstruction.
This is a retrospective, cross-sectional study. Twelve patients with atrial switch repair for TGA were examined. Azygos flow index was measured with phase-contrast magnetic resonance imaging; comparison was made between patients with documented systemic venous baffle obstruction (n=3) and a control group of patients without baffle obstruction (n=9).
Patients with systemic venous baffle obstruction had a distinctive azygos flow pattern that was retrograde and an increased amount of azygos flow compared with patients without obstruction [median (range), -436 (-455/-399) vs. 103 (51/125) mL/min/m2; P=0.01].
Patients with systemic venous baffle obstruction have a characteristic collateral flow across the azygos vein. Azygos vein flow measurement may be used for the assessment of baffle patency in patients after atrial switch repair for TGA. However, diagnostic accuracy needs to be tested in a larger population.
Mots-clé
Adolescent, Adult, Azygos Vein/physiopathology, Blood Flow Velocity/physiology, Cross-Sectional Studies, Female, Heart Atria/surgery, Humans, Magnetic Resonance Imaging/methods, Male, Retrospective Studies, Statistics, Nonparametric, Transposition of Great Vessels/surgery
Pubmed
Web of science
Création de la notice
15/11/2017 17:10
Dernière modification de la notice
23/02/2024 15:04
Données d'usage