An overview on extremity dosimetry in medical applications

Details

Ressource 1Download: REF.pdf (116.83 [Ko])
State: Public
Version: Final published version
License: Not specified
It was possible to publish this article open access thanks to a Swiss National Licence with the publisher.
Serval ID
serval:BIB_E0FD441EB9C4
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
An overview on extremity dosimetry in medical applications
Journal
Radiation Protection Dosimetry
Author(s)
Vanhavere F., Carinou E., Donadille L., Ginjaume M., Jankowski J., Rimpler A., Sans Merce M.
ISSN
0144-8420 (Print)
ISSN-L
0144-8420
Publication state
Published
Issued date
2008
Volume
129
Number
1-3
Pages
350-355
Language
english
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't ; Review
Publication Status: ppublish
Abstract
Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some of these applications, the skin of the fingers is the limiting organ for individual monitoring of external radiation. Therefore, sub-group 1 of WG9 deals with the use of extremity dosemeters in medical radiation fields. The wide variety of radiation field characteristics present in a medical environment together with the difficulties in measuring a local dose that is representative for the maximum skin dose, usually with one single detector, makes it difficult to perform accurate extremity dosimetry. Sub-group 1 worked out a thorough literature review on extremity dosimetry issues in diagnostic and therapeutic nuclear medicine and positron emission tomography, interventional radiology and interventional cardiology and brachytherapy. Some studies showed that the annual dose limits could be exceeded if the required protection measures are not taken, especially in nuclear medicine. The continuous progress in new applications and techniques requires an important effort in radiation protection and training.
Keywords
Extremities/radiation effects, Occupational Exposure/analysis, Radiation Monitoring/methods, Radiation Protection/methods
Pubmed
Web of science
Open Access
Yes