Evaluation of the Achieve Mapping Catheter in cryoablation for atrial fibrillation: a prospective randomized trial.

Details

Serval ID
serval:BIB_BED9E0E4DC1B
Type
Article: article from journal or magazin.
Collection
Publications
Title
Evaluation of the Achieve Mapping Catheter in cryoablation for atrial fibrillation: a prospective randomized trial.
Journal
Journal of interventional cardiac electrophysiology
Author(s)
Gang Y., Gonna H., Domenichini G., Sampson M., Aryan N., Norman M., Behr E.R., Zuberi Z., Dhillon P., Gallagher M.M.
ISSN
1572-8595 (Electronic)
ISSN-L
1383-875X
Publication state
Published
Issued date
03/2016
Peer-reviewed
Oui
Volume
45
Number
2
Pages
179-187
Language
english
Notes
Publication types: Journal Article ; Randomized Controlled Trial ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
The purpose of this study is to establish the role of Achieve Mapping Catheter in cryoablation for paroxysmal atrial fibrillation (PAF) in a randomized trial.
A total of 102 patients undergoing their first ablation for PAF were randomized at 2:1 to an Achieve- or Lasso-guided procedure. Study patients were systematically followed up for 12 months with Holter monitoring. Primary study endpoint was acute procedure success. Secondary endpoint was clinical outcomes assessed by AF free at 6 and 12 months after the procedure.
Of 102 participants, 99 % of acute procedure success was achieved. Significantly shorter procedure duration with the Achieve-guided group than with the Lasso-guided group (118 ± 18 vs. 129 ± 21 min, p < 0.05) was observed as was the duration of fluoroscopy (17 ± 5 vs. 20 ± 7 min, p < 0.05) by subgroup analysis focused on procedures performed by experienced operators. In the whole study patients, procedure and fluoroscopic durations were similar in the Achieve- (n = 68) and Lasso-guided groups (n = 34). Transient phrenic nerve weakening was equally prevalent with the Achieve and Lasso. No association was found between clinical outcomes and the mapping catheter used. The use of second-generation cryoballoon (n = 68) reduced procedure time significantly compared to the first-generation balloon (n = 34); more patients were free of AF in the former than the latter group during follow-up.
The use of the Achieve Mapping Catheter can reduce procedure and fluoroscopic durations compared with Lasso catheters in cryoablation for PAF after operators gained sufficient experience. The type of mapping catheter used does not affect procedure efficiency and safety by models of cryoballoon.
Keywords
Adult, Aged, Aged, 80 and over, Atrial Fibrillation/diagnosis, Atrial Fibrillation/surgery, Body Surface Potential Mapping/instrumentation, Body Surface Potential Mapping/methods, Cardiac Catheterization/instrumentation, Cardiac Catheterization/methods, Cryosurgery/instrumentation, Cryosurgery/methods, Disease-Free Survival, Equipment Design, Equipment Failure Analysis, Female, Humans, Male, Middle Aged, Operative Time, Prospective Studies, Surgery, Computer-Assisted/instrumentation, Surgery, Computer-Assisted/methods, Treatment Outcome, Young Adult, AF ablation, Circular mapping catheter, Cryoablation, Cryoballoon, Randomized controlled trial
Pubmed
Web of science
Create date
03/03/2024 18:58
Last modification date
11/03/2024 8:17
Usage data