"Standing waves": diagnostic differentiel de la dysplasie fibromusculaire. ["Standing waves": differential diagnosis of fibromuscular dysplasia]

Details

Serval ID
serval:BIB_B566CCE2E6A9
Type
Article: article from journal or magazin.
Publication sub-type
Case report (case report): feedback on an observation with a short commentary.
Collection
Publications
Institution
Title
"Standing waves": diagnostic differentiel de la dysplasie fibromusculaire. ["Standing waves": differential diagnosis of fibromuscular dysplasia]
Journal
Helvetica Chirurgica Acta
Author(s)
Joseph  J. M., Doenz  F., Mosimann  F.
ISSN
0018-0181 (Print)
Publication state
Published
Issued date
12/1994
Volume
60
Number
6
Pages
897-9
Notes
Case Reports
English Abstract
Journal Article --- Old month value: Dec
Abstract
We report two recent observations of an angiographic artefact called "standing waves". It results in the same characteristic beaded pictures than fibromuscular dysplasia. It is induced by the angiography catheter and is related to the speed of injection. The possible occurrence of this artefact should be borne in mind whenever the films show dysplastic lesions in more than one artery.
Keywords
Adult *Angiography Artifacts Diagnosis, Differential Female Fibromuscular Dysplasia/*radiography Humans Hypertension, Renovascular/radiography Intermittent Claudication/radiography Middle Aged