Haemodynamic changes during high frequency oscillation for respiratory distress syndrome
Details
Serval ID
serval:BIB_A90754027639
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Haemodynamic changes during high frequency oscillation for respiratory distress syndrome
Journal
Archives of Disease in Childhood. Fetal and Neonatal Edition
ISSN
1359-2998 (Print)
Publication state
Published
Issued date
05/1996
Volume
74
Number
3
Pages
F172-6
Notes
Clinical Trial
Controlled Clinical Trial
Journal Article --- Old month value: May
Controlled Clinical Trial
Journal Article --- Old month value: May
Abstract
In a crossover trial left ventricular output (LVO), cerebral blood flow velocity (CBFV), and resistance index (RI) of the anterior cerebral artery were compared using Doppler ultrasonography, in eight preterm infants with respiratory distress syndrome (RDS) during conventional mechanical ventilation and high frequency oscillation. LVO was 14% to 18% lower with high frequency oscillation. There were no significant changes in CBFV. On the first day of life there was a trend towards lower RI on high frequency oscillation; the fall in LVO on high frequency oscillation was not related to lung hyperinflation. Changes in ventilation type (from conventional mechanical ventilation to high frequency oscillation, or vice versa) can induce significant LVO changes in preterm infants with RDS.
Keywords
Blood Flow Velocity
Blood Gas Analysis
Brain/blood supply
Cardiac Output
Cross-Over Studies
Hemodynamic Processes
*High-Frequency Ventilation
Humans
Infant, Newborn
Infant, Premature
Lung/physiology
Respiratory Distress Syndrome, Newborn/*therapy/ultrasonography
Ultrasonography, Doppler
Vascular Resistance
Ventricular Function, Left
Pubmed
Web of science
Open Access
Yes
Create date
25/01/2008 10:23
Last modification date
20/08/2019 15:13