Comparison of non-parametric T<sub>2</sub> relaxometry methods for myelin water quantification.

Details

Serval ID
serval:BIB_99A4A4271BB8
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Comparison of non-parametric T<sub>2</sub> relaxometry methods for myelin water quantification.
Journal
Medical image analysis
Author(s)
Canales-Rodríguez E.J., Pizzolato M., Piredda G.F., Hilbert T., Kunz N., Pot C., Yu T., Salvador R., Pomarol-Clotet E., Kober T., Thiran J.P., Daducci A.
ISSN
1361-8423 (Electronic)
ISSN-L
1361-8415
Publication state
Published
Issued date
04/2021
Peer-reviewed
Oui
Volume
69
Pages
101959
Language
english
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
Multi-component T <sub>2</sub> relaxometry allows probing tissue microstructure by assessing compartment-specific T <sub>2</sub> relaxation times and water fractions, including the myelin water fraction. Non-negative least squares (NNLS) with zero-order Tikhonov regularization is the conventional method for estimating smooth T <sub>2</sub> distributions. Despite the improved estimation provided by this method compared to non-regularized NNLS, the solution is still sensitive to the underlying noise and the regularization weight. This is especially relevant for clinically achievable signal-to-noise ratios. In the literature of inverse problems, various well-established approaches to promote smooth solutions, including first-order and second-order Tikhonov regularization, and different criteria for estimating the regularization weight have been proposed, such as L-curve, Generalized Cross-Validation, and Chi-square residual fitting. However, quantitative comparisons between the available reconstruction methods for computing the T <sub>2</sub> distribution, and between different approaches for selecting the optimal regularization weight, are lacking. In this study, we implemented and evaluated ten reconstruction algorithms, resulting from the individual combinations of three penalty terms with three criteria to estimate the regularization weight, plus non-regularized NNLS. Their performance was evaluated both in simulated data and real brain MRI data acquired from healthy volunteers through a scan-rescan repeatability analysis. Our findings demonstrate the need for regularization. As a result of this work, we provide a list of recommendations for selecting the optimal reconstruction algorithms based on the acquired data. Moreover, the implemented methods were packaged in a freely distributed toolbox to promote reproducible research, and to facilitate further research and the use of this promising quantitative technique in clinical practice.
Keywords
Myelin water imaging, Non-negative least squares, T(2) relaxometry, Tikhonov regularization, Tissue microstructure
Pubmed
Web of science
Open Access
Yes
Create date
22/02/2021 12:11
Last modification date
12/06/2021 6:34
Usage data