The importance of sonographer experience and machine quality with regards to the role of musculoskeletal ultrasound in routine care of rheumatoid arthritis patients.

Details

Serval ID
serval:BIB_8BA3EB69D913
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
The importance of sonographer experience and machine quality with regards to the role of musculoskeletal ultrasound in routine care of rheumatoid arthritis patients.
Journal
Clinical and Experimental Rheumatology
Author(s)
Brulhart L., Ziswiler H.R., Tamborrini G., Zufferey P., SONAR/SCQM programmes 
Contributor(s)
SONAR/SCQM programmes 
ISSN
0392-856X (Print)
ISSN-L
0392-856X
Publication state
Published
Issued date
2015
Peer-reviewed
Oui
Volume
33
Number
1
Pages
98-101
Language
english
Notes
Publication types: Journal Article Publication Status: ppublish
Abstract
OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care.
METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers.
RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion).
CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.
Pubmed
Web of science
Create date
18/04/2015 13:41
Last modification date
20/08/2019 15:50
Usage data