Diagnostic performance of 2-[18F]FDG PET/CT in recurrent differentiated thyroid cancer and elevated antithyroglobulin antibodies: an updated systematic review and bivariate meta-analysis.
Details
Serval ID
serval:BIB_7A59DD60EAD2
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Diagnostic performance of 2-[18F]FDG PET/CT in recurrent differentiated thyroid cancer and elevated antithyroglobulin antibodies: an updated systematic review and bivariate meta-analysis.
Journal
Endocrine
ISSN
1559-0100 (Electronic)
ISSN-L
1355-008X
Publication state
In Press
Peer-reviewed
Oui
Language
english
Notes
Publication types: Journal Article ; Review
Publication Status: aheadofprint
Publication Status: aheadofprint
Abstract
This updated systematic review and bivariate meta-analysis aimed to investigate the diagnostic performance of 2-[ <sup>18</sup> F]FDG PET/CT for the detection of recurrent disease in patients with differentiated thyroid cancer (DTC) who have negative <sup>131</sup> I whole body scintigraphy and increased antithyroglobulin antibodies (TgAb) levels.
The current systematic review was carried out following a preset protocol, and the "Preferred Reporting Items for a Systematic Review and Meta-Analysis" served as a guideline for its development and reporting. A comprehensive research of the PubMed/MEDLINE, Embase and Cochrane library databases was conducted until June 2024.
Between 2002 and 2023, 13 studies (608 patients) published on this topic were selected. The pooled sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 2-[ <sup>18</sup> F]FDG PET or PET/CT were 84% (95%CI: 78-87%), 82% (95%CI: 78-86%), 72% (95%CI: 67-76%), 90% (95%CI: 87-93%) and 83% (95%CI: 79%-86%) respectively. The pooled positive and negative likelihood ratios (LR+ and LR - ) and the diagnostic odds ratio (DOR) were 0.180 (95%CI: 0.128-0.253), 3.214 (95%CI: 2.357-4.383), and 17.863 (95%CI: 10.475-30.462), respectively. No statistically significant heterogeneity among the studies was found for all the metrics evaluated (I <sup>2</sup> < 50%).
2-[ <sup>18</sup> F]FDG PET/CT demonstrated a good diagnostic performance in patients with DTC and increased TgAb. Although more studies are warranted, the provided evidence-based data should support the integration of 2-[ <sup>18</sup> F]FDG PET/CT in clinical and diagnostic guidelines on DTC patients with increased TgAb.
The current systematic review was carried out following a preset protocol, and the "Preferred Reporting Items for a Systematic Review and Meta-Analysis" served as a guideline for its development and reporting. A comprehensive research of the PubMed/MEDLINE, Embase and Cochrane library databases was conducted until June 2024.
Between 2002 and 2023, 13 studies (608 patients) published on this topic were selected. The pooled sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 2-[ <sup>18</sup> F]FDG PET or PET/CT were 84% (95%CI: 78-87%), 82% (95%CI: 78-86%), 72% (95%CI: 67-76%), 90% (95%CI: 87-93%) and 83% (95%CI: 79%-86%) respectively. The pooled positive and negative likelihood ratios (LR+ and LR - ) and the diagnostic odds ratio (DOR) were 0.180 (95%CI: 0.128-0.253), 3.214 (95%CI: 2.357-4.383), and 17.863 (95%CI: 10.475-30.462), respectively. No statistically significant heterogeneity among the studies was found for all the metrics evaluated (I <sup>2</sup> < 50%).
2-[ <sup>18</sup> F]FDG PET/CT demonstrated a good diagnostic performance in patients with DTC and increased TgAb. Although more studies are warranted, the provided evidence-based data should support the integration of 2-[ <sup>18</sup> F]FDG PET/CT in clinical and diagnostic guidelines on DTC patients with increased TgAb.
Keywords
18f-fdg, Anti-thyroglobulin antibody, Dtc, Pet/ct, Thyroid cancer, 18F-FDG, DTC, PET/CT
Pubmed
Open Access
Yes
Create date
13/09/2024 15:34
Last modification date