Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT.

Details

Ressource 1Download: 10.1177_2058460116662299.pdf (401.86 [Ko])
State: Public
Version: Final published version
Serval ID
serval:BIB_7A00B26E440F
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT.
Journal
Acta radiologica open
Author(s)
Barras H., Dunet V., Hachulla A.L., Grimm J., Beigelman-Aubry C.
ISSN
2058-4601 (Print)
Publication state
Published
Issued date
08/2016
Peer-reviewed
Oui
Volume
5
Number
8
Pages
2058460116662299
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
Model-based iterative reconstruction (MBIR) reduces image noise and improves image quality (IQ) but its influence on post-processing tools including maximal intensity projection (MIP) and minimal intensity projection (mIP) remains unknown.
To evaluate the influence on IQ of MBIR on native, mIP, MIP axial and coronal reformats of reduced dose computed tomography (RD-CT) chest acquisition.
Raw data of 50 patients, who underwent a standard dose CT (SD-CT) and a follow-up RD-CT with a CT dose index (CTDI) of 2-3 mGy, were reconstructed by MBIR and FBP. Native slices, 4-mm-thick MIP, and 3-mm-thick mIP axial and coronal reformats were generated. The relative IQ, subjective IQ, image noise, and number of artifacts were determined in order to compare different reconstructions of RD-CT with reference SD-CT.
The lowest noise was observed with MBIR. RD-CT reconstructed by MBIR exhibited the best relative and subjective IQ on coronal view regardless of the post-processing tool. MBIR generated the lowest rate of artefacts on coronal mIP/MIP reformats and the highest one on axial reformats, mainly represented by distortions and stairsteps artifacts.
The MBIR algorithm reduces image noise but generates more artifacts than FBP on axial mIP and MIP reformats of RD-CT. Conversely, it significantly improves IQ on coronal views, without increasing artifacts, regardless of the post-processing technique.

Keywords
Multidetector computed tomography (MDCT), image reconstruction, thorax
Pubmed
Web of science
Open Access
Yes
Create date
28/09/2016 18:40
Last modification date
20/08/2019 15:36
Usage data